HOW TO ADJUST THERMOSTAT
(For electrically heated urns)
THERMOSTAT CALIBRATION
Your thermostat should be calibrated if it cycles off
before the urn reaches the brewing range on the dial
thermometer (200° - 205°F) or if the urn reaches a
boiling point.
To Calibrate Thermostat:
1. Turn control to off position and remove black knob.
2. With a small screwdriver, turn screw "A" clockwise
to decrease and counter-clockwise to increase the
temperature.
3. Adjusting the calibration screw
1/4
turn will increase
or decrease the temperature approximately 10°F.
4. Replace knob and turn thermostat back to the No.
10 position and check to see if it is calibrated
properly. When the thermostat is in the No. 10
position — dial thermometer should stay in the
brewing range.
5 LSQ