18
19
information
i
information
i
FORMAT
ERRORS
(error level)
LONG ID
(long bleep)
BITSPRE
(decode algorithm)
BLKMESS
(default message review method)
Block message review
allows all the messages in the
store to be read at once in sequence. If the offer to
DELETE? is accepted then all the messages are erased.
Individual message review
allows individual messages to
be selected, read and deleted.
USRGRPS
(user groups)
VIBRATE
IMPORTANT
Send a programming call for the required Individual
Code from the system encoder
.
When the new code appears release the button
The pager will show the Group Codes (GC) in sequence.
To add a Group Code press
while it is displayed.
Send a programming call from the system encoder
.
When the new code appears release the button. The
display will change to show the next Group Code.
If you wish to add another Group Code press
and
send a programming call.
If you do not wish to make changes do not press the
button and allow the pager to return to normal operation.
The display shows a number
between 0 and 8 which indicated
the number of non-correctable
errors that are permissible in each
message block before a message is
rejected as unusable. If a message
is rejected in this way the call is
disregarded and the pager does not
respond. Corrupted characters are
shown as blanks.
Select this option to allow the user
to choose either the normal bleep
time, 5 s or a long bleep time, 24 s.
This is an engineering function only
and must be set to 6.
This screen will allow you to set the
default message review facility.
Select a tick to default to BLOCK
MESSAGES or a cross to default to
INDIVIDUAL MESSAGES. You can
temporarily change the setting from
the "user selectable functions" (page
9). If you switch the pager off it will
revert to the default setting the next
time that it is switched on.
Select USRGRPS to allow the user
to join or leave any of the groups
programmed into the pager.
This selects the vibrator (where
fitted).
FORMAT is an engineering function
and is normally set in the factory.
The format letter shown MUST
correspond to the format setting in
the system encoder. The default
setting is C.
This will save the settings.
Continued from previous page
The pager will accept a maximum
of 6 group codes.
This will save the settings.