Maintenance: 

 

Cleaning 

The RIMS Rocket™ electric recirculation heater will require cleaning after use. First confirm the custom 
molded plug is disconnected from the RIMS Rocket™ electric recirculation heater and is disconnected 
from any power source. Use hot water and Five Star Chemical’s Powdered Brewery Wash or similar 
detergent with a scrub brush or ScotchBrite™ scouring pad to remove any heavy soil deposits. 
Periodically remove the RIMS Rocket™ electric recirculation heater from the lid to remove build-up of 
mineral deposits. If you brew with particularly hard water, you may need to use a weak acid, such as 
distilled white vinegar, to assist with removing mineral deposits.  The terminal pins of the RIMS 
Rocket™ electric immersion heater can tolerate incidental contact with water in the course of cleaning, 
however, never immerse or soak the terminal pins of the RIMS Rocket™ in water or cleaning solutions.  
 
Before and after each use, inspect the RIMS Rocket™ electric recirculation heater, custom molded plug, 
cable, and connectors for wear or damage. If any of the above parts show signs of wear or damage, 
discontinue use and contact your Blichmann Engineering™ authorized retailer for replacement parts. 
 

Warning:

 ALWAYS make sure the RIMS Rocket™ electric recirculation heater is disconnected from all 

power sources before cleaning. 
 

Warning:

 NEVER immerse or soak the terminal pins of the RIMS Rocket™ in water or cleaning 

solutions. Doing so can cause permanent damage to the heater and create an unsafe condition which 
can result in personal property damage, injury, electrocution or death. ALWAYS allow the RIMS 
Rocket™ electric recirculation heater to thoroughly dry after cleaning and before reinstalling. 
 

Caution:

 Never use chlorine bleach or H-Cl acid to clean your RIMS Rocket™ electric recirculation 

heater. Pitting in the surface of the heater coil and/or bulkhead fittings caused by the use of products 
containing chlorine or H-Cl acid is not covered under the warranty. 

Summary of Contents for RIMS Rocket

Page 1: ...ed Warning can lead to serious injury or death if not followed Please read these thoroughly and understand them completely before use If you do not understand them or have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Do NOT at ANY time operate the product until you thoroughly read and understand these instructions Caution Sections labeled Cau...

Page 2: ...s as well as the basic tools required for assembly Please carefully review the lists below to ensure you received all of the correct parts and have the required tools prior to assembly Parts List Item Quantity Item Quantity Heater Coil 1 Heater Cable Assembly 1 Bulkhead Nut 5 8 18 Jam Nut 2 S70 208 O ring 2 Plug Guard 1 Lid 1 2 Pressure Relief Plug 1 Required Tools 7 8 Deep Well Socket and Ratchet...

Page 3: ...nut with a 7 8 deep well socket and ratchet as shown in Figure 2 Tighten both bulkhead retaining nuts before proceeding Step Three Place the large black O ring provided with your HopRocket over the heater coil and locate it in the recessed portion of the lid Next remove all internal components from the HopRocket canister and install the canister over the heater coil and situate it on the lid and l...

Page 4: ...S Rocket may be compatible with other commercially available brewing controllers the Tower of Power electric temperature control module provides the ultimate in safety convenience accuracy and precision To operate the RIMS Rocket electric recirculation heater you must verify your system can maintain a minimum flow rate of of a gallon per minute If you are unable to achieve the minimum flow rate th...

Page 5: ...ket canister is oriented in a safe direction in the event of over pressurization Do not stand or allow children or pets in the area directly below the RIMS Rocket electric recirculation heater and HopRocket canister ALWAYS orient the pressure relief device as shown in Figure Op 2 Make sure the flange of the silicone pressure relief plug is located on the same side of the lid as the plug protector ...

Page 6: ... cable and provide more convenient cable routing Warning NEVER operate the RIMS Rocket electric recirculation heater without the plug protector installed Warning NEVER plug the RIMS Rocket electric recirculation heater directly into a power source ALWAYS use a power control device capable of de energizing the heater coil Figure Op 3 Warning NEVER plug in or unplug the heater cord from the heater c...

Page 7: ...n heater is specifically designed for use with the Tower of Power electric temperature control module which provides the perfect means of controlling temperature and power Important The ability to maintain required flow rates and modulate is necessary to prevent scorching Warning The outlet of the RIMS Rocket electric recirculation heater must always be unobstructed and open to atmospheric pressur...

Page 8: ...higher than rated voltage NEVER unplug heater when energized NEVER energize the heater without the heating coils fully submerged NEVER immerse the terminal pins in water or cleaning solutions ALWAYS ALWAYS use heater with rated voltage ALWAYS unplug heater when de energized ALWAYS use on level and stable hard surfaces ALWAYS connect to a GFCI circuit ALWAYS check power cables and connectors for si...

Page 9: ... pins of the RIMS Rocket in water or cleaning solutions Before and after each use inspect the RIMS Rocket electric recirculation heater custom molded plug cable and connectors for wear or damage If any of the above parts show signs of wear or damage discontinue use and contact your Blichmann Engineering authorized retailer for replacement parts Warning ALWAYS make sure the RIMS Rocket electric rec...

Page 10: ...RIMS Rocket Owner s Manual V1 Blichmann Engineering LLC 2014 Expolded Parts Diagram ...

Page 11: ...d B Limitations of Warranty 1 Any implied warranty that is found to arise by way of state or federal law including any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty o...

Reviews: