Step One: 

First remove both bulkhead nuts from the heater 
coil. Next install the heater coil through the lid and 
plug guard as shown in Figure 1. Make certain the lid 
is oriented as show or the RIMS Rocket™ electric 
recirculation heater will not seal. Last, re-install the 
bulkhead nuts finger tight. 
 

Warning: 

NEVER install the RIMS Rocket™ electric 

recirculation heater without the plug guard. Doing 
so can result in personal property damage, injury, 
electrocution and death. 
 

 

Figure1 

 

Figure 2  

Step Two:

 

Using a 1” open end or adjustable wrench, hold the 
bulkhead fitting while tightening the bulkhead 
retaining nut with a 7/8” deep well socket and 
ratchet as shown in Figure 2. Tighten both 
bulkhead retaining nuts before proceeding. 

 

Step Three: 

Place the large black O-ring provided with 
your HopRocket™ over the heater coil and 
locate it in the recessed portion of the lid. 
Next, remove all internal components from 
the HopRocket™ canister and install the 
canister over the heater coil and situate it on 
the lid and large black O-ring seal as shown in 
Figure 3. Lastly, install the band clamp and T-
handle nut as per the instructions provided in 
the HopRocket™ Owner’s Manual. 
 

Caution:

 ALWAYS apply a lubricant such as 

petroleum jelly, food grade silicone grease, or 
mineral oil to the draw bolt and T-handle nut 
to prevent the threads from seizing. Thread 
galling is not covered under warranty. 

 

Figure 3 

Large Black O-ring 

Bulkhead 

Nut 

Plug 

Protector 

Lid 

Terminal 

Pin

Bulkhead 

Fitting 

Summary of Contents for RIMS Rocket

Page 1: ...ed Warning can lead to serious injury or death if not followed Please read these thoroughly and understand them completely before use If you do not understand them or have any questions contact your retailer or Blichmann Engineering www BlichmannEngineering com before use Do NOT at ANY time operate the product until you thoroughly read and understand these instructions Caution Sections labeled Cau...

Page 2: ...s as well as the basic tools required for assembly Please carefully review the lists below to ensure you received all of the correct parts and have the required tools prior to assembly Parts List Item Quantity Item Quantity Heater Coil 1 Heater Cable Assembly 1 Bulkhead Nut 5 8 18 Jam Nut 2 S70 208 O ring 2 Plug Guard 1 Lid 1 2 Pressure Relief Plug 1 Required Tools 7 8 Deep Well Socket and Ratchet...

Page 3: ...nut with a 7 8 deep well socket and ratchet as shown in Figure 2 Tighten both bulkhead retaining nuts before proceeding Step Three Place the large black O ring provided with your HopRocket over the heater coil and locate it in the recessed portion of the lid Next remove all internal components from the HopRocket canister and install the canister over the heater coil and situate it on the lid and l...

Page 4: ...S Rocket may be compatible with other commercially available brewing controllers the Tower of Power electric temperature control module provides the ultimate in safety convenience accuracy and precision To operate the RIMS Rocket electric recirculation heater you must verify your system can maintain a minimum flow rate of of a gallon per minute If you are unable to achieve the minimum flow rate th...

Page 5: ...ket canister is oriented in a safe direction in the event of over pressurization Do not stand or allow children or pets in the area directly below the RIMS Rocket electric recirculation heater and HopRocket canister ALWAYS orient the pressure relief device as shown in Figure Op 2 Make sure the flange of the silicone pressure relief plug is located on the same side of the lid as the plug protector ...

Page 6: ... cable and provide more convenient cable routing Warning NEVER operate the RIMS Rocket electric recirculation heater without the plug protector installed Warning NEVER plug the RIMS Rocket electric recirculation heater directly into a power source ALWAYS use a power control device capable of de energizing the heater coil Figure Op 3 Warning NEVER plug in or unplug the heater cord from the heater c...

Page 7: ...n heater is specifically designed for use with the Tower of Power electric temperature control module which provides the perfect means of controlling temperature and power Important The ability to maintain required flow rates and modulate is necessary to prevent scorching Warning The outlet of the RIMS Rocket electric recirculation heater must always be unobstructed and open to atmospheric pressur...

Page 8: ...higher than rated voltage NEVER unplug heater when energized NEVER energize the heater without the heating coils fully submerged NEVER immerse the terminal pins in water or cleaning solutions ALWAYS ALWAYS use heater with rated voltage ALWAYS unplug heater when de energized ALWAYS use on level and stable hard surfaces ALWAYS connect to a GFCI circuit ALWAYS check power cables and connectors for si...

Page 9: ... pins of the RIMS Rocket in water or cleaning solutions Before and after each use inspect the RIMS Rocket electric recirculation heater custom molded plug cable and connectors for wear or damage If any of the above parts show signs of wear or damage discontinue use and contact your Blichmann Engineering authorized retailer for replacement parts Warning ALWAYS make sure the RIMS Rocket electric rec...

Page 10: ...RIMS Rocket Owner s Manual V1 Blichmann Engineering LLC 2014 Expolded Parts Diagram ...

Page 11: ...d B Limitations of Warranty 1 Any implied warranty that is found to arise by way of state or federal law including any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty o...