Software Setup
72
ER41, ER24
Functional Profiles Supported by the Drive
I/O Profile
Using the I/O profile simplifies PLC programming.
The I/O profile mirrors the use of the terminal strip for control by utilizing 1 bit to control a function.
The I/O profile for the drive can also be used when controlling via a fieldbus.The drive starts up as soon as
the
run
command is sent.15 bits of the control word (bits 1...15) can be assigned to a specific function.
This profile can be developed for simultaneous control of the drive via:
The terminals
The Modbus control word
The CANopen control word
Ethernet Modbus TCP embedded
The fieldbus module control word
The I/O profile is supported by the drive itself and therefore in turn by all the communication ports
(integrated Modbus, CANopen, Ethernet, PROFIBUS DP, PROFINET, and DeviceNet fieldbus modules).
CiA402 Profile
The drive only starts up following a command sequence.
The control word is standardized.
5 bits of the control word (bits 11...15) can be assigned to a function.
The CiA402 profile is supported by the drive itself and therefore by all the communication ports (Modbus,
CANopen, Ethernet, PROFIBUS DP, PROFINET, and DeviceNet).
The drive supports the
velocity
mode of CiA402 profile.
In the CiA402 profile, there are two modes that are specific to the drive and characterize commands and
references value management:
Separate
[Separate]
(
)
Not separate
[Not separ.]
(
),
Summary of Contents for ER41
Page 1: ...ER41 ER24 PROFINET Manual 08 2017 www blemo com ...
Page 8: ...8 ER41 ER24 ...
Page 14: ...Presentation 14 ER41 ER24 ...
Page 30: ...Basics 30 ER41 ER24 ...
Page 102: ...Software Setup 102 ER41 ER24 ...
Page 103: ...Software Setup 103 ER41 ER24 ...
Page 104: ...Software Setup 104 ER41 ER24 ...
Page 112: ...Operation 112 ER41 ER24 ...
Page 125: ......
Page 126: ......