Maintenance
OPTIONAL FAN ASSEMBLY
Routine maintenance of the OPTIONAL Fan Assembly on the back of the stove is not required. However, should it
become necessary to replace an individual fan from your local dealer.
PAINT
If the finish on the stove ever becomes blemished, you can repaint with high temperature paint available from your
dealer. DO NOT paint the stove while it is HOT.
RHEOSTAT REPLACEMENT
The fan rheostat seldom fails. But, if it does, follow this procedure after obtaining a BLAZE KING replacement rheostat.
1.
Unplug the fan power cord from the wall.
2.
Remove the four screws on the fan cage containing the rheostat switch.
3.
Remove the blower from the cage, DO NOT DISCONNECT THE WIRES; locate the two wires coming from the
rheostat switch.
4.
Unplug the two wires from the rheostat switch.
5.
Pull the knob straight off the switch.
6.
Unscrew the nut holding the switch to the cage.
7.
Replace the switch, making sure the small position locating pin is fitted into the hole in the cage.
8.
To reinstall the switch, reverse the above steps being sure to tuck the wires back into the assembly so they do not
come in contact with the fan blade.
THERMOMETER
The catalyst thermometer, with its built-in lag of 4-8 minutes, tells you what was happening 4-8 minutes ago. And
remember, it is only an indication of the temperatures of the gasses, after they pass through the catalyst. The
thermometer probe, the part that fits into the stove, must be cleaned at least once a year. Lift it from the stove (be
careful, it may be hot) and wipe or scrape it clean. At room temperature, away from the stove, the indicator should point
near the bottom of the "Inactive" zone. If, after several years use, you find that the needle no longer points to the bottom
of the "Inactive" zone when the thermometer has been at room temperature for 10 minutes or longer, it may need
adjustment. Holding the probe with a pair of pliers, loosen the bolt on the top of the dial. Turn the dial to align the pointer
with the bottom of the "Inactive" zone, then retighten the bolt.
Note:
If your Blaze King is equipped with optional fans, turn off fans and wait 10 minutes prior to reading catalytic
thermometer indicator. Air movement across the top of the stove may provide false reading.
THERMOSTAT
Under normal operations, the thermostat should be set on a mid-range setting. At this setting the stove is capable of
heating an average size home. The thermostat is adjusted at the factory and should not be tampered with. If the
thermostat breaks, the damper will automatically close.