MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS)
Either Rear Shield OR Fan kit are required for these installations (See next page for kits and part numbers).
Mobile home installations also requires the Outside Air Kit: Z1726B. They are easiest to mount before the
stove is installed. See instructions packed with each kit.
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed
precisely. You must also purchase (from the same manufacturer) and install the ceiling support package, fire
stops (when needed), insulation shield, roof flashing, chimney cap, etc. Maintain the proper clearance to the
structure as recommended by the manufacturer.
Chimney connector must be double wall close clearance type, and must be of same brand and model as listed
prefabricated chimney. Single wall pipe is not allowed in Mobile Homes or in Alcove Installations. Insulated
chimney components must be a listed factory built chimney suitable for use with solid fuels and conforming to,
ULC629 in Canada or UL-103HT in the USA. For Mobile home, the chimney need to be removable to allow
for transportation of the mobile home.
MOBILE HOME:
WARNING - DO NOT INSTALL IN SLEEPING ROOM
CAUTION - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND
CEILING/ROOF MUST BE MAINTAINED.
INSTALLATION INSTRUCTIONS
In mobile home installations, the stove must be securely fastened to the floor using the
tie-downs provided in the Outside Air kit.
(To access the screw down hole, remove side
shields (see page 23)).
ALSO, a #8 ground wire must be attached to the stove and an appropriate ground.
View of tie-down right side
stove, same for left side.