Version 1.03
April 2011
Chinook CBT
Page 14
G:\pubdata\Manuals\English Manuals\OM-CK24
OM CK24C/CK24F
G = 4” in USA
H = 16” in USA
I = 0” in USA
K = 18” for single wall pipe in Canada
8” in Canada
18” in Canada
8” in Canada
(If K=18”, J=84” Minimum)
MINIMUM CLEARANCES FOR CHINOOK WITH
FLAT
SIDESHIELDS (CK24F)
Ember protection shield (not required to have an insulation value) need to have a minimum size of:
In USA:
43 1/4” x 34 3/4” (1100 x 908mm)
In Canada:
53 1/4” x 42 3/4” (1353 x 1086mm)
Min. Alcove minimum width 48”, maximum depth 48”, minimum height 72”
INSTALLATION INSTRUCTIONS
A
G
C
I
B
D
G
H
2"
Residential Installations
A
B
C
D
E
F
J
Roof exit, parallel and corner. No Fan kit required
10.75”
6”
20.6”
13.65”
*
4”
14.5”
*
72”
Wall exit, parallel and corner. No Fan kit required.
10.75”
6”
20.6”
13.65”
*
4”
14.5”
*
74”
*
Alcove, roof or wall exit. Use either fan kit or rear
shield and double wall pipe.
10.75”
6”
20.6”
13.65”
72”
Mobile Home Installation
Roof exit, parallel and corner Use either fan kit or
rear shield, double wall pipe and outside air kit
10.75”
6”
20.6”
13.65”
4”
14.5”
72”
* Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single
wall pipe is required.
This stove must be installed in compliance with all local codes and regulations.