background image

8

www.blaubergventilatoren.de

FRESHBOX 60

OUT

OUT

OUT

OUT

IN

L

L1

L2

L3

L4

1

1

2

3

4

5

PE

L

N

+12V

GND

+12V

+12V GND DIR PWM

+12V GND DIR PWM

GND

PE

L

N

+

-

INFL

OW_PWM

OUTFL

OW_PWM

INFL

OW_DIR

5

4

3

2

1

2

2

1

1

GND

NTC

M2

(supply fan)

M1

(exhaust fan)

RT1

NTC_10K

5

4

3

2

1

+

-

iD

iP

0

P

N N

L L

L3

L2

L1

speed

3

speed

2

speed

1

2

3

N

L

PE

N

L

PE

N

L

PE

yellow-green

brown
yellow 
green 
white

Input voltage: 110-240V

Output current: 1 A

red 

blue 

yello

whit

red 

blue 

yello

whit

High
Middle
Low

Contact 

Circuit

Sticker

Contact Circuit Sticker

Con

tac

Cir

cuit

Sticker

Con

tac

Cir

cuit

Sticker

Fig.11. Sensor speed switch SGR-3/1

Fig. 12. Wiring diagram

 CONNECTION TO POWER MAINS AND CONTROL

The unit is rated for connection to single-phase alternating current power 

mains 1~100-240 V / 50-60 Hz.

The power cable is pre-wired to the unit to facilitate electric connection. 

The unit is equipped with BLAUBERG SGR-3/1 sensor speed switch for 

operation mode control. 

The sensor speed switch BLAUBERG SGR-3/1 is designed for switching on/off 

and operation mode selection: 

 

mode 1

. The speed switch is in 1 position. Air flow 30 m3/h.

 

mode 2

. The speed switch is in 2 position. Air flow 45 m3/h.

 

mode 3

. The speed switch is in 3 position. Air flow 60 m3/h.

Touch a respective speed button to activate a required speed of the connected 

air handling unit. 

Touch a respective speed button to change the selected speed. The respective 

speed button has blue highlighting. Touch a current fan speed button once 

again to turn the air handling unit off. 

The sensor panel has no light indication when the unit is off. Every time the 

sensor panel is touched a sound signal is generated. 

The control unit is installed under the protecting panel of the air handling unit, 

fig. 12.

The air handling unit is connected to the sensor speed switch via a four-wire 

wire, 3 m long, that is included into the delivery set. 12. 

Each wire must have min. section 0.25 mm

2

. The cable length from the unit to 

the sensor speed switch must not exceed 30 m.

!

WARNING

Read the operation manual prior to any electric installations. Connection of the unit to power mains is allowed by a 

qualified electrician only.

The rated electrical parameter are stated on the rating plate. No modifications of internal connections are allowed and will result in void 

warranty.

Connect the unit only to power mains with valid electric standards. The unit must be connected to a correct mounted socket with a 

grounded terminal or connected to a fixed installed cable.

Follow the respective electric standards, safety rules (DIN VDE 0100), TAB der EVUs.
The house cabling system must be equipped with an automatic switch at the external input. Connect the unit to power mains through the 

automatic switch. The contact gap on all poles at least 3 mm (VDE 0700 T1 7.12.2 / EN 60335-1). 

Install the automatic switch to ensure prompt access.

Summary of Contents for FRESHBOX 60

Page 1: ...OPERATION MANUAL FRESHBOX 60 SINGLE ROOM AIR HANDLING UNIT WITH HEAT RECOVERY ...

Page 2: ...ansportation rules 3 Manufacturer s warranty 3 Unit design and operating logic 4 Delivery set 4 Technical data 5 Mounting and operation guidelines 5 Connection to power mains and control 8 Maintenance 9 Troubleshooting 9 Acceptance certificate 10 Connection certificate 10 Warranty card 10 CONTENTS ...

Page 3: ...ection Technical data Do not close or block the unit intake or exhaust vent not to disturb the normal air passage Do not sit on the unit and do not put objects on the unit Follow the manual guidelines to ensure trouble free operation and long service life of the product Hazardous parts access and water ingress protection standard IP22 STORAGE AND TRANSPORTATION RULES Transportation of the unit is ...

Page 4: ...g efficiency reaches 79 The air flows are fully separated within the heat exchanger Odours and con taminants contained in the extract air are not transferred to the supply air flow Heat recovery is based on the utilization of the thermal energy of the ex tract air for heating up the supply air The extract air transfers most of its heat to the intake air flow This reduces thermal energy losses in c...

Page 5: ... construction stage It includes two plastic air ducts each 500 mm long and two master plates for marking the holes on inner and outer wall sides The mounting set MS2 FRESHBOX 60 is specially designed for mounting of the unit in a ready built premise It includes two plastic air ducts 500 mm long a master plate for matching holes and an outer ventilation hood AH FRESHBOX 60 that prevents ingress of ...

Page 6: ... the solidification time in the product specification remove the master plates At the inner wall cut the protruding parts of the air ducts to be flush with the wall On outer wall side the air ducts must protrude by 10 mm to prevent condensate dropping on the wall 7 Mounting sequence of the unit a take off the front cover and remove the heat exchanger fig 8 b connect the unit spigots to the air duc...

Page 7: ... mounting set includes plastic air duct Ø 125 mm 500 mm long 2 items paper master plate 1 item outer ventilation box AH FRESHBOX 60 1 item screw and dowel 8x40 4 items Mounting sequence of MS2 FRESHBOX 60 set 1 Fix the master plate from the delivery set on inner wall side with a sealing tape on required level fig 5 2 Use the master plate to mark two Ø 140 mm holes for the air ducts and two Ø 8 mm ...

Page 8: ...uch a respective speed button to change the selected speed The respective speed button has blue highlighting Touch a current fan speed button once again to turn the air handling unit off The sensor panel has no light indication when the unit is off Every time the sensor panel is touched a sound signal is generated The control unit is installed under the protecting panel of the air handling unit fi...

Page 9: ...peed switch mounting Mounting sequence of the sensor speed switch fig 13 1 Carefully undo the latches of the switch front panel with a screwdriver 2 Remove the front panel 3 Route the cable to the installation place of the speed switch 4 Fix the back panel to the wall through the fixing holes 5 Connect the control cable to the speed switch following the wiring diagram fig 12 6 Install the speed sw...

Page 10: ...rective 2006 95 EC 73 23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date____________________ The single room air handling unit with heat recovery FRESHBOX 60 is connected to power ma...

Page 11: ..._______________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ ________________...

Page 12: ...www blaubergventilatoren de FRESHBOX 60 v 5 3 EN ...

Reviews: