FRESHBOX 60

BLAUBERG Ventilation GmbH

 is happy to offer your attention a new high-

quality single room air handling unit with heat recovery FRESHBOX 60. 

The solid team of high-qualified professionals with many years of working 

experience, technological innovations in design and production, high-quality 

components and materials from the top worldwide producers have become 

the precondition for the best single room air handling unit in its class.

INTRODUCTION

The present service instruction contains technical description, technical data 

sheets, operation and mounting guidelines, safety precautions and warnings 

for safe and correct operation of the unit. 

GENERAL

The single-room unit is designed for efficient energy saving supply and 

exhaust ventilation of flats, houses, cottages and other small premises.
The unit is for wall mounting. 
The unit is designed for continuous operation always connected to power 

mains.

SAFETY RULES

The unit complies with the requirements according to the EU norms and 

directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 
All operations related to the unit electrical connections, servicing and repair 

works are allowed only after the unit is disconnected from power mains. 
All mounting and servicing operations are allowed for duly qualified 

electricians with valid electrical work permit for electric operations at the 

units up to 1000 V after careful study of the present user's manual.
The unit must be grounded! 
Please follow the safety regulations and working instructions (DIN EN 50 110, 

IEC 364).
Make sure the impeller and the casing are not damaged before connecting 

the unit to power mains. The casing internals must be free of any foreign 

objects which can damage the impeller blades.
Disconnect the unit from power mains prior to any operations related to the 

init servicing and repair works.
Take measures to prevent contact with the fan to avoid physical damages 

during the unit test and start-up. 
Misuse of the product or any unauthorized modification are not allowed. 
The unit is designed for connection to AC single-phase power mains, see 

"Technical Data". The unit is rated for permanent operation during non-stop 

power supply. 
Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney flues or other 

fire-protection devices. Sufficient air supply must be provided for proper 

combustion and exhaust of gases through the chimney of fuel burning 

equipment to prevent back drafting.  The maximum permitted pressure 

difference per living units is 4 Pa.
The transported air must not contain any dust or other solid impurities, 

sticky substances or fibrous materials. The unit is not designed for use in an 

inflammable and explosive medium. 
The transported air must not have an aggressive effect on steel at the 

temperature stated in the table 1 of the section “Technical data”.
Do not close or block the unit intake or exhaust vent not to disturb the 

normal  air passage. Do not sit on the unit and do not put objects on the unit.
Follow the manual guidelines to ensure trouble-free operation and long 

service life of the product.
Hazardous parts access and water ingress protection standard IP22. 

STORAGE AND TRANSPORTATION RULES

Transportation of the unit is allowed by any vehicle provided the unit is 

transported in the original package and is protected against weather and 

mechanical damages. 
Use hoist machinery for handling and transportation to prevent possible 

mechanical damages of the unit. Fulfil the requirements for transportation of 

the specified cargo type during cargo-handling operations. 
Store the unit in a dry and cool place in the original packing.
The storage environment must not be subjected to any aggressive and/

or chemical evaporations, admixtures, foreign objects that may provoke 

corrosion and damage connection tightness. 
Store the unit in an environment with minimized risk of mechanical damages, 

temperature and humidity fluctuations. 
Do not expose the unit to the temperatures below  +5°C and above  +40 °C .
Connection of the unit to power mains is allowed after the unit has been kept 

indoor for minimum two hours.

MANUFACTURER'S WARRANTY

The product complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 
We hereby declare that the following product complies with the essential 

protection requirements of Electromagnetic Council Directive 2004/108/

EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and 

CE-marking Directive 93/68/EEC on the approximation of the laws of the 

Member States relating to electromagnetic compatibility. 
The manufacturer hereby warrants normal operation of the unit over 

the period of 2 years from the retail sale date provided observance of the 

installation and operation regulations.
In case of failure due to manufacturing fault during the warranty period the 

consumer has the right to exchange it.
If case of no confirmation of the sale date, the warranty period shall be 

calculated from the manufacturing date.
The replacement is offered by the Seller. 
The manufacturer shall not be liable for any damage resulting from any 

misuse of or gross mechanical interference with the unit.
Fulfil the operation manual requirements to ensure a trouble-free and long 

service life of the unit.

 

              WARNING

 

Do not dispose in domestic waste. 

The unit contains in part material that can be recycled 
and in part substances that should not end up as domestic 
waste.

Dispose of the unit once it has reached the end of its 
working life according to the regulations valid where you 
are.

 

                  ATTENTION

 

The product is not allowed for use by children and persons with reduced 
physical, mental or sensory capacities, without proper practical 
experience or expertise, unless they are controlled or instructed on the 
product operation by the person(s) responsible for their safety. Supervise 
the children and do not let them play with the product. 

!

Summary of Contents for FRESHBOX 60

Page 1: ...OPERATION MANUAL FRESHBOX 60 SINGLE ROOM AIR HANDLING UNIT WITH HEAT RECOVERY ...

Page 2: ...ansportation rules 3 Manufacturer s warranty 3 Unit design and operating logic 4 Delivery set 4 Technical data 5 Mounting and operation guidelines 5 Connection to power mains and control 8 Maintenance 9 Troubleshooting 9 Acceptance certificate 10 Connection certificate 10 Warranty card 10 CONTENTS ...

Page 3: ...ection Technical data Do not close or block the unit intake or exhaust vent not to disturb the normal air passage Do not sit on the unit and do not put objects on the unit Follow the manual guidelines to ensure trouble free operation and long service life of the product Hazardous parts access and water ingress protection standard IP22 STORAGE AND TRANSPORTATION RULES Transportation of the unit is ...

Page 4: ...g efficiency reaches 79 The air flows are fully separated within the heat exchanger Odours and con taminants contained in the extract air are not transferred to the supply air flow Heat recovery is based on the utilization of the thermal energy of the ex tract air for heating up the supply air The extract air transfers most of its heat to the intake air flow This reduces thermal energy losses in c...

Page 5: ... construction stage It includes two plastic air ducts each 500 mm long and two master plates for marking the holes on inner and outer wall sides The mounting set MS2 FRESHBOX 60 is specially designed for mounting of the unit in a ready built premise It includes two plastic air ducts 500 mm long a master plate for matching holes and an outer ventilation hood AH FRESHBOX 60 that prevents ingress of ...

Page 6: ... the solidification time in the product specification remove the master plates At the inner wall cut the protruding parts of the air ducts to be flush with the wall On outer wall side the air ducts must protrude by 10 mm to prevent condensate dropping on the wall 7 Mounting sequence of the unit a take off the front cover and remove the heat exchanger fig 8 b connect the unit spigots to the air duc...

Page 7: ... mounting set includes plastic air duct Ø 125 mm 500 mm long 2 items paper master plate 1 item outer ventilation box AH FRESHBOX 60 1 item screw and dowel 8x40 4 items Mounting sequence of MS2 FRESHBOX 60 set 1 Fix the master plate from the delivery set on inner wall side with a sealing tape on required level fig 5 2 Use the master plate to mark two Ø 140 mm holes for the air ducts and two Ø 8 mm ...

Page 8: ...uch a respective speed button to change the selected speed The respective speed button has blue highlighting Touch a current fan speed button once again to turn the air handling unit off The sensor panel has no light indication when the unit is off Every time the sensor panel is touched a sound signal is generated The control unit is installed under the protecting panel of the air handling unit fi...

Page 9: ...peed switch mounting Mounting sequence of the sensor speed switch fig 13 1 Carefully undo the latches of the switch front panel with a screwdriver 2 Remove the front panel 3 Route the cable to the installation place of the speed switch 4 Fix the back panel to the wall through the fixing holes 5 Connect the control cable to the speed switch following the wiring diagram fig 12 6 Install the speed sw...

Page 10: ...rective 2006 95 EC 73 23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date____________________ The single room air handling unit with heat recovery FRESHBOX 60 is connected to power ma...

Page 11: ..._______________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ ________________...

Page 12: ...www blaubergventilatoren de FRESHBOX 60 v 5 3 EN ...