This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the Ceileo DC unit and 
all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery set ........................................................................................................................................................................................ 4
Designation key .............................................................................................................................................................................. 4
Technical data .................................................................................................................................................................................. 5
Design and operating principle ........................................................................................................................................... 6
Mounting and set-up .................................................................................................................................................................. 7
Connection to power mains .................................................................................................................................................. 10
Control ................................................................................................................................................................................................. 11
Technical maintenance .............................................................................................................................................................. 12
Storage and transportation regulations .......................................................................................................................... 14
Manufacturer’s warranty ........................................................................................................................................................... 15
Certificate of acceptance .......................................................................................................................................................... 19
Seller information .......................................................................................................................................................................... 19
Installation certificate .................................................................................................................................................................. 19
Warranty card ................................................................................................................................................................................... 19

CONTENTS

All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing 
and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are 

allowed for installation. The present user’s manual should be carefully read before 

beginning works.

Check the unit for any visible damage of the impeller, the casing, and the grille before starting 
installation. The casing internals must be free of any foreign objects that can damage the 
impeller blades. 
While mounting the unit, avoid compression of the casing! Deformation of the casing may result 
in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 
materials.

SAFETY REQUIREMENTS

Summary of Contents for Ceileo Compact DC 110 light

Page 1: ...Ceileo DC 110 H IR Ceileo DC 110 Light H IR Ceileo DC 150 H IR Ceileo DC 150 Light H IR Centrifugal ceiling fan USER S MANUAL EN...

Page 2: ...rranty card 19 CONTENTS All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed whe...

Page 3: ...r use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of th...

Page 4: ...s favourable for the formation of hazardous substances toxic substances dust pathogenic germs NAME QUANTITY Fan 1 pc LED lamp for fans with the Light option 2 pcs Cable gland 1 pc Mounting bracket 4 p...

Page 5: ...es described in this manual Ceileo 150 DC T H IR A E H d D L2 L1 B C A E H B L1 L2 d D h C b a A E C B D H h L1 A E C h B H L1 D b a Ceileo 110 DC Light T H IR Ceileo 150 DC Light T H IR h Ceileo 110...

Page 6: ...110 254 150 Noise level 3 m dB A Sones from 23 0 3 up 25 0 7 from 23 0 3 up 29 1 0 Weight kg 6 4 5 3 6 2 5 1 IP 2X 2X SEC class B B only for the Light modifications TECHNICAL DATA Ceileo 110 150 DC T...

Page 7: ...detected more the fan keeps running for a set turn off delay time adjustable from 1 to 90 minutes and the reverts to the initial operation status Humidity sensor H If the indoor humidity exceeds the s...

Page 8: ...he H models with a humidity sensor remove the protective cap from the grille prior to its installation Route the contact socket of the sensor H or IR via the opening in the grille and connect the sens...

Page 9: ...ation to one of the ceiling joists Installation between the ceiling joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for...

Page 10: ...E FAN L2 L1 N L N LT N L N L 100 240 V 50 60 Hz 100 240 V 50 60 Hz 1 2 3 4 5 6 7 LIGHT contact socket is available only for the models with LED light FAN 1 QF QF Remove the decorative grille For acces...

Page 11: ...menu Once the button is pressed the indicator displays the turn on delay timer setting which can be edited with the buttons and Once the button is pressed again the setup menu is displayed again and...

Page 12: ...available for the fan with the air capacity 110 CFM Example 1 with these activated settings the fan runs to keep the air flow 60 CFM Once the switch is turned on or a sensor is activated the fan star...

Page 13: ...of the sensors from the respective sockets on the control unit applicable for TH and TP models 2 Take off the surface mounted luminaire Press the holders on the reverse side of the grille frame and t...

Page 14: ...at the air ducts are not damaged Make sure that the air dampers and louvre shutters are open STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dry...

Page 15: ...he Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual inclu...

Page 16: ...www blaubergventilatoren de Ceileo DC 16...

Page 17: ...www blaubergventilatoren de Ceileo DC 17...

Page 18: ...www blaubergventilatoren de Ceileo DC 18...

Page 19: ...IFICATE The unit _____________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation T...

Page 20: ...www blaubergventilatoren de B166EN 02...

Reviews: