MICROPROCESSOR CONTROL UNIT WITH INDICATION
Indicator
Buttons
Connection
socket for humidity sensor
Connection
socket for motion sensor
The DC fan motor is operated by the microprocessor control unit. The front panel of the control unit comprises a light indicator, control
buttons and two sockets for connection of the humidity sensor and motion sensor.
After the fan is connected to power supply, the indicator displays
for two seconds. After that the light indicator goes off and the fan
starts operating in a set mode. Once the button is pressed, the indicator displays the turn-off delay timer setting
, the first setup
menu entry. Use the buttons
or
to navigate in the setup menu. Press the button
to select a current entry in the setup menu.
After that the indicator displays the selected parameter value (e.g., turn-off delay timer setting). Use the buttons
or
to edit the
setting. Press the button
to come back to the setup menu. If no button is pressed for 60 seconds, the indicator goes down.
Example
The indicator displays
. Once the button
is pressed, the setup menu list goes one position down and the symbol
is displayed
(refer to the setup menu).
Once the button
is pressed, the indicator displays the turn-on delay timer setting, which can be edited with the buttons
and
.
Once the button
is pressed again, the setup menu is displayed again and the edited value is saved. To reset the menu to the factory
settings press and hold the buttons
and
synchronously. In 5 seconds the indicator displays
and goes off. The fan keeps
running normally with the factory settings.
INDICATOR SYMBOLS OF THE MICROPROCESSOR CONTROL UNIT
: turn-off delay timer adjustable from 1 to 90 minutes (default setting 15 minutes)
: turn-on delay timer adjustable from 0 to 180 seconds with the increment of 10 seconds (default setting 0)
: humidity set point adjustable from 50% up to 90% (default setting 75%)
: access to submenu of the fan operation mode
Operation mode
: the fan operates without any activation signal from the switch, humidity or motion sensor.
Operation mode
: the fan operates with activation signal from the switch, humidity or motion sensor.
: back to the upper setup menu level.
Once the switch is turned on or the humidity or motion sensor is activated, the fan switches from the mode
to the mode
.
After no signal is received more from the sensor in case of the indoor humidity normalization or no motion detection or in case of the fan
shutdown the fan keeps running for a set turn-off delay time and then switches from the mode
to the mode
.
CONTROL