background image

The warranty is exclusively limited to the defects of workmanship.  
Any and all defects and malfunctions including mechanical damage caused by physical 
contact in the course of operation or natural wear and tear shall not be deemed warranty 
cases.  
The warranty liabilities shall not cover any malfunctions resulting from disregard of the 
instructions specific to the operation, care and maintenance of the unit or any 
unauthorised alterations and modifications to the unit design made by the user or any 
third party.  
Furthermore, the warranty shall not apply to any damage resulting from accidents, 
lightning strike, water, fire, war, public disorder or any other factors beyond the reasonable 
control of the manufacturer and its official distributors.  

RELATED DAMAGE LIABILITY WAIVER  

The manufacturer shall not be liable for any deterioration of health or damage to 
equipment caused by violating the provisions of the present User's Manual, unit misuse or 
gross mechanical tampering.  
The company does not provide compensation for any related damage (e.g. unit relocation 
and re-connection, direct or indirect damages etc.) related to the unit replacement.  
The manufacturer's warranty shall not cover any and all transportation expenses or any 
other expenses including the risks specific to unit deactivation, transportation and 
installation.  
The warranty for mounting, electrical equipment installation and adjustment work must 
be provided by the respective contractor.  
In any case the compensation under the present warranty may not exceed the amount 
actually paid for the faulty unit by the buyer.  

www.blaubergventilatoren.de

13

Box-D

Summary of Contents for 4058448013898

Page 1: ...Box D USER S MANUAL EN CEILING FAN ...

Page 2: ... device operation by the person responsible for their safety The fan may not be used to handle air containing highly flammable substances or vapours such as alcohol petrol etc The fans take 220 240 V 50 60 Hz single phase alternating current Children being supervised not to play with the appliance Disconnect the damper from the power supply electric mains prior to any work on the unit Power mains ...

Page 3: ...e must not exceed the limit values given in Table 1 The fan is designed for installation between the floor slab and the suspended ceiling attached to the ceiling structure on mounting brackets or to a wall on side mounts Box D 100 and Box D 125 only The fan is designed for extended periods of continuous operation without disconnection from power mains The products meet the requirements of IPX4 haz...

Page 4: ...uency Hz Power W Current A 3 Maximum air capacity m h R P M Sound pressure level at 3 m distance dB A o Max transported air temperature C IP rating Fan type Dimensions mm Weight kg Box D 125 L Box D 125 Box D 100 L Box D 100 Box D 150 Fan type Pict 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 2 Box D 160 Box D 100 L Box D 100 Box D 125 L Box D 1...

Page 5: ...rille 5 with air filter 6 is attached to the casing with screws Decorative front panel 7 locks into the slots on grille 5 The casing houses a single phase electric motor with a centrifugal impeller and backward curved blades The electric motor has integrated thermal protection and restarts automatically The replacement of parts of the safety suspension system device shall be performed by the manuf...

Page 6: ...e suspended ceiling must be within 165 390 mm The fan installation steps are given in Fig 5 6 The power is supplied via an external terminal box mounted to the fan casing WARNING If unusual oscillating movement is observed immediately stop using the ceiling fan and contact the manufacturer its service agent or suitably qualified persons The fan is to be installed so that the blades are more than 2...

Page 7: ...280 mm S 1 3 5 7 2 4 6 8 Box D 100 L Box D 100 Box D 125 L Box D 125 Figure 5 www blaubergventilatoren de 7 Box D ...

Page 8: ...8 www blaubergventilatoren de Box D S 403 5 mm 250 mm Box D 150 Box D 160 1 3 5 2 4 6 Figure 6 ...

Page 9: ...st be equipped with a switch built into the stationary wiring to disconnect all the mains phases The location of the S external switch must ensure unobstructed access for shutting down the fan quickly if required The conductor cross section values are given for reference only while the actual selection must be based on the maximum permissible wire heating which depends on the wire type its insulat...

Page 10: ...ated inside the fan casing in accordance with the Wiring Diagram and the terminal designations Fig 7 The terminal designation diagram is given on a label inside the terminal box 2 3 4 The steps for connecting the fan to power mains are given on Fig 8 L N X1 1 2 3 N L S 220 240 V 50 60 Hz 4 Figure 7 Figure 8 ...

Page 11: ...acement steps are given in Fig 9 The impeller blades must be thoroughly cleaned from dust and dirt every 6 months Take the necessary measures to prevent penetration of smoke carbon monoxide and other combustion products into the spaces through open smoke ducts or other fire safety infrastructure as well as prevent back flow of gases from any appliances which produce gas flame or naked flame The tr...

Page 12: ...of a faulty unit being the subject of warranty repair application replaced over the warranty period shall inherit the warranty period and warranty service terms which apply to the entire unit For the avoidance of doubt this means that neither the said components nor the entire unit shall be covered by an additional warranty period In the event of any malfunctions in the fan operation during the wa...

Page 13: ...turer and its official distributors RELATED DAMAGE LIABILITY WAIVER The manufacturer shall not be liable for any deterioration of health or damage to equipment caused by violating the provisions of the present User s Manual unit misuse or gross mechanical tampering The company does not provide compensation for any related damage e g unit relocation and re connection direct or indirect damages etc ...

Page 14: ...nical codes and standards The fan operates normally as intended by the manufacturer Signature Installation Company Stamp Unit Type CEILING FAN Model Box D ____________ Serial Number Manufacture Date is compliant with the technical specifications and is hereby declared ready for service We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council...

Page 15: ...Unit Type CEILING FAN Model Box D _________ Serial Number Purchase Date Warranty Period Seller Seller s Stamp WARRANTY CARD WARRANTY CARD Purchase Date www blaubergventilatoren de 15 Box D ...

Page 16: ...www blaubergventilatoren de ...

Reviews: