background image

12

www.blaubergventilatoren.de

Box-D

MANUFACTURER'S WARRANTY 

We hereby declare that the product complies with the essential protection requirements of 
Electromagnetic Council Directive 20

1

4/

30

/E

U

 and Low Voltage Directive 

20

14

/

35

/E

U

 and CE-marking Directive 93/68/EEC on the approximation of the laws 

of the Member States relating to electromagnetic compatibility.
This certificate is issued following test carried out on samples of the product referred to above. 
By purchasing the product the buyer accepts the following warranty terms and conditions: 
The Manufacturer hereby guarantees normal performance of the fan during 24 months 
from the date of retail sale provided compliance with transport, storage, mounting and 
operation regulations. 
To benefit from the warranty service you must produce the original User's Manual containing 
the unit manufacture date as well as the original receipt or other documentary evidence of the 
fact equipment purchase and its date.  
The unit model must be consistent with the one stated in the User's Manual. In the absence 
of a receipt with the purchased date or any documentary evidence of the equipment ownership 
and purchase date the warranty period shall be calculated from the manufacture date stated 
in the User's Manual. 
Should the User completely fail to provide the documents listed above the company reserves 
the right to deny free warranty service of a faulty unit.  
All the units and components being part of a faulty unit (being the subject of warranty repair 
application) replaced over the warranty period shall inherit the warranty period and warranty 
service terms which apply to the entire unit.  
For the avoidance of doubt this means that neither the said components nor the entire unit 
shall be covered by an additional warranty period.  
In the event of any malfunctions in the fan operation during the warranty period which occur 
through the manufacturer's fault, the user shall be entitled to claim fan replacement at the 
factory. Please contact the Seller regarding any matters related to warranty service. 
The warranty liabilities shall not apply to the accessories used with the unit irrespective of their 
being part of the fan delivery package and any and all damage caused to other equipment 
operated in conjunction with the unit. The company shall not be liable for ensuring 
compatibility of its products with third-party units as far as their compatibility is concerned.  

STORAGE REGULATIONS 

The fans must be stored in the original packing in a well-ventilated area at temperatures 
from +5 °C to +40 °C and relative air humidity up to 80 % (at Т= +20 °C).  

The unit is not intended for operation in environments with high concentrations of highly 
flammable substances or vapours such as alcohol, petrol, insecticides etc. 
Do not close or block the inlet and outlet openings of the unit to ensure optimum air flow. 
Do not sit on the unit or put any objects on top of it. The unit owner must follow this manual.  

Precautions must be taken to avoid the backflow of gases into the room from the
open flue of gas or other fuel-burning appliances (for duct and partition fans)!

Summary of Contents for 4058448013898

Page 1: ...Box D USER S MANUAL EN CEILING FAN ...

Page 2: ... device operation by the person responsible for their safety The fan may not be used to handle air containing highly flammable substances or vapours such as alcohol petrol etc The fans take 220 240 V 50 60 Hz single phase alternating current Children being supervised not to play with the appliance Disconnect the damper from the power supply electric mains prior to any work on the unit Power mains ...

Page 3: ...e must not exceed the limit values given in Table 1 The fan is designed for installation between the floor slab and the suspended ceiling attached to the ceiling structure on mounting brackets or to a wall on side mounts Box D 100 and Box D 125 only The fan is designed for extended periods of continuous operation without disconnection from power mains The products meet the requirements of IPX4 haz...

Page 4: ...uency Hz Power W Current A 3 Maximum air capacity m h R P M Sound pressure level at 3 m distance dB A o Max transported air temperature C IP rating Fan type Dimensions mm Weight kg Box D 125 L Box D 125 Box D 100 L Box D 100 Box D 150 Fan type Pict 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 2 Box D 160 Box D 100 L Box D 100 Box D 125 L Box D 1...

Page 5: ...rille 5 with air filter 6 is attached to the casing with screws Decorative front panel 7 locks into the slots on grille 5 The casing houses a single phase electric motor with a centrifugal impeller and backward curved blades The electric motor has integrated thermal protection and restarts automatically The replacement of parts of the safety suspension system device shall be performed by the manuf...

Page 6: ...e suspended ceiling must be within 165 390 mm The fan installation steps are given in Fig 5 6 The power is supplied via an external terminal box mounted to the fan casing WARNING If unusual oscillating movement is observed immediately stop using the ceiling fan and contact the manufacturer its service agent or suitably qualified persons The fan is to be installed so that the blades are more than 2...

Page 7: ...280 mm S 1 3 5 7 2 4 6 8 Box D 100 L Box D 100 Box D 125 L Box D 125 Figure 5 www blaubergventilatoren de 7 Box D ...

Page 8: ...8 www blaubergventilatoren de Box D S 403 5 mm 250 mm Box D 150 Box D 160 1 3 5 2 4 6 Figure 6 ...

Page 9: ...st be equipped with a switch built into the stationary wiring to disconnect all the mains phases The location of the S external switch must ensure unobstructed access for shutting down the fan quickly if required The conductor cross section values are given for reference only while the actual selection must be based on the maximum permissible wire heating which depends on the wire type its insulat...

Page 10: ...ated inside the fan casing in accordance with the Wiring Diagram and the terminal designations Fig 7 The terminal designation diagram is given on a label inside the terminal box 2 3 4 The steps for connecting the fan to power mains are given on Fig 8 L N X1 1 2 3 N L S 220 240 V 50 60 Hz 4 Figure 7 Figure 8 ...

Page 11: ...acement steps are given in Fig 9 The impeller blades must be thoroughly cleaned from dust and dirt every 6 months Take the necessary measures to prevent penetration of smoke carbon monoxide and other combustion products into the spaces through open smoke ducts or other fire safety infrastructure as well as prevent back flow of gases from any appliances which produce gas flame or naked flame The tr...

Page 12: ...of a faulty unit being the subject of warranty repair application replaced over the warranty period shall inherit the warranty period and warranty service terms which apply to the entire unit For the avoidance of doubt this means that neither the said components nor the entire unit shall be covered by an additional warranty period In the event of any malfunctions in the fan operation during the wa...

Page 13: ...turer and its official distributors RELATED DAMAGE LIABILITY WAIVER The manufacturer shall not be liable for any deterioration of health or damage to equipment caused by violating the provisions of the present User s Manual unit misuse or gross mechanical tampering The company does not provide compensation for any related damage e g unit relocation and re connection direct or indirect damages etc ...

Page 14: ...nical codes and standards The fan operates normally as intended by the manufacturer Signature Installation Company Stamp Unit Type CEILING FAN Model Box D ____________ Serial Number Manufacture Date is compliant with the technical specifications and is hereby declared ready for service We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council...

Page 15: ...Unit Type CEILING FAN Model Box D _________ Serial Number Purchase Date Warranty Period Seller Seller s Stamp WARRANTY CARD WARRANTY CARD Purchase Date www blaubergventilatoren de 15 Box D ...

Page 16: ...www blaubergventilatoren de ...

Reviews: