8. Technical data
BMP-215E
400V
BMP-215E
230V
BMP-215E
110V
BMP-215B
Power consumption
1.8 kW
1.8 kW
1.8 kW
4 kW at 3600 min
-1
Electrical connection / fuel
400V / 50 Hz
For CEE plug 5-
pol. Fuse
protection 16A
230V / 50 Hz
For shock proof plug.
Fuse protection 16A
110V / 50 Hz
For shock proof
plug. Fuse
protection 31A
Unleaded petrol
Octane 86 or higher
Lubricant:
SAE 10W-30
Working width
215 mm
215 mm
215 mm
215 mm
Rotation speed drum
1700 min
-1
1700 min
-1
1700 min
-1
1700 min
-1
Length
900 mm
900 mm
900 mm
900 mm
Width
380 mm
380 mm
380 mm
380 mm
Height
1160 mm
1160 mm
1160 mm
1160 mm
Weight
58 kg
58 kg
58 kg
58 kg
Sound at operators pos.
Uncertainty
LpA 98 dB(A)
K 5 dB(A)
LpA 98 dB(A)
K 5 dB(A)
LpA 98 dB(A)
K 5 dB(A)
LpA 98 dB(A)
K 5 dB(A)
Sound power level
Uncertainty
LwA 111 dB(A)
K 5 dB(A)
LwA 111 dB(A)
K 5 dB(A)
LwA 111 dB(A)
K 5 dB(A)
LwA 111 dB(A)
K 5 dB(A)
Vibration level
Uncertainty
a
hv
5,8 m/s²
K 0,9 m/s²
a
hv
5,8 m/s²
K 0,9 m/s²
a
hv
5,8 m/s²
K 0,9 m/s²
a
hv
5,8 m/s²
K 0,9 m/s²
Ambient temperature
-5°C ~ 40°C
-5°C ~ 40°C
-5°C ~ 40°C
-5°C ~ 40°C
Dust hose connection
Ø50 mm
Ø50 mm
Ø50 mm
Ø50 mm
Suitable filter unit
Contact Blastrac BV
We will assist you with a good advice
Design and specifications are subject to change without notice by Blastrac BV
IMPORTANT NOTES:
Noise and vibration measurements were taken during heavy operation on concrete. The noise and vibration
levels depend on the working depth, which is in turn determined by the unevenness of the surface. The impact
force of the tools onto the surface is the biggest factor in both noise and vibration levels.
The indicated values are measured on new machines. Noise and vibration levels will vary in different
circumstances. Area influences like open outside or closed inside space, ambient temperature, different
surfaces to be treated, daily use, different tools or accessories, poor maintenance, etc. will give different
values at all time and could increase the exposure level over the total working period.
The declared vibration and noise emission levels represent the main applications of the machine. The values
may be measurements from a representative sample of technically comparable machinery. The values may be
used for a preliminary assessment of exposure.
A precise estimation of the level of exposure to vibration and noise should also take in account the times when
the machine is switched off or even running, but not actually in use. This may significantly decrease the