Shaking the primary filter
Figure 7-8
Depending on the vacuumed dust quantity and if the pointer of
the vacuum gauge switches from the green zone (
3
, Fig. 7) to
the red zone (
2
, Fig. 7), turn the vacuum cleaner off and shake
the main filter with the knob (
1
, Fig. 8).
WARNING!
Stop the vacuum cleaner before shaking the filter.
Do not shake the filter while the vacuum cleaner is on,
as this could damage the filter itself.
Wait a few seconds before restarting the vacuum cleaner,
to allow the dust to settle. Replace the filter element if the
pointer still remains in the red zone (
1
, Fig. 7) even after the
filter has been shaken (consult the “Primary filter replacement”
paragraph).
Emergency stopping
Turn the main switch to “0” position.
Protective casing opening and replacement
of hazardous dust bags
WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
WARNING!
■
These operations can only be carried out by
trained and qualified personnel who must wear
adequate clothing, in compliance with the laws in
force.
■
Take care not to raise dust when this operation is
carried out. Wear a P3 protective mask.
■
In case of hazardous and/or harmful dust, use
only the bags recommended by the manufacturer
(see “Recommended spare parts”).
■
The bag must only be disposed of by qualified
personnel and in compliance with the laws in
force.
Figure 9 - 10
■
Press down the lever (
2,
Fig. 9) to release the casing (
1,
Fig. 9).
■
With the lever (
3,
Fig. 9) lift the casing (
1,
Fig. 9) to reach
the bag (
4,
Fig. 9).
■
Turn the bag full of dust (
1,
Fig. 10) on itself to obtain a
section of coiled bags to be tightened with two clamps (
2,
Fig. 10).
■
Place the two clamps at a distance of 50 mm between
them, then with a pair of scissors cut between the two
clamps.
■
Remove the bag full of dust (
1,
Fig. 10) and place the
new section of Longopac
®
(
3,
Fig. 10).
At the end of a cleaning session
■
Turn off the vacuum cleaner and remove the plug from
the socket.
■
Wind the connection cable around the handle (Fig. 11).
■
Clean the vacuum cleaner as described in the
“Maintenance, cleaning and decontamination” paragraph.
■
Store the device in a dry place, out of reach of
unauthorized people.
■
Shut the inlet with the appropriate plug (
10
, Fig. 1) when
the vacuum cleaner is transported or not being used.
Summary of Contents for BDC-3155HCA
Page 2: ......
Page 18: ...Operating manual BDC 3155HCA 16 16 info blastrac eu I...
Page 34: ...Operating manual BDC 3155HCA 16 16 info blastrac eu GB...
Page 50: ...Manuel d utilisation BDC 3155HCA 16 16 info blastrac eu F...
Page 66: ...Betriebshandbuch BDC 3155HCA 16 16 info blastrac eu D...
Page 82: ...Manual de uso BDC 3155HCA 16 16 info blastrac eu E...
Page 98: ...Bedieningshandleiding BDC 3155HCA 16 16 info blastrac eu NL...
Page 100: ...Operating manual BDC 3155HCA info blastrac eu 3 A C B 4 1 5 I 0 9 8 9 4 7 3 6 2...
Page 101: ...Operating manual BDC 3155HCA info blastrac eu 5 1 2 I 0 2 1 RED 3 GREEN 1 7 6 1 8...
Page 102: ...Operating manual BDC 3155HCA info blastrac eu 2 1 3 4 1 3 2 9 10 3 50 mm 1 2 2 11...
Page 103: ...Operating manual BDC 3155HCA info blastrac eu 12 1 I 0 3 4 5 6 7 8 6 10 50 mm 9 10 10...
Page 104: ...Operating manual BDC 3155HCA info blastrac eu 11 12 25 13 14 15 16 17 18 19 20 12...
Page 105: ...Operating manual BDC 3155HCA info blastrac eu 12 21 22 21 23 50 mm 24...
Page 106: ...Operating manual BDC 3155HCA info blastrac eu 26 27 28 29 30 28 28 29 29 28 31 29 28 12...
Page 107: ...Operating manual BDC 3155HCA info blastrac eu 13 4 1 5 6 3 2 7 8 9 10 11 12...
Page 108: ...Operating manual BDC 3155HCA info blastrac eu 14 1 2 3 5 4...
Page 109: ...Operating manual BDC 3155HCA info blastrac eu 16 1 2 15 1 2...
Page 112: ...Operating manual BDC 3155HCA info blastrac eu...