background image

3

ATB 19x

Part N

o

: 9848.xx

ASI - TV Transmodulator

ASI 

 ATV (AM)  

The manual instructions of the Headend Controller HCB x00 and the Bus Extender BEB x00 have to be considered!

4. Front view

5. Function description

With this transmodulator, the digital ASI signal is decoded and then transferred into a serial data stream. Next, that data stream is
parallelised and fed into a FIFO system. The timing of this data input will in all cases be calculated from how full the FIFO system is
and adapted to the general data input rate. The regeneration system for the transport stream SPI protocol follows at the FIFO system 
output, and at the same time, recognition of the transport stream being correct is ensured. It is at this level that the transport stream 
can be edited.From the transport stream, the succeeding MPEG decoder selects a programme and generates an analogue video 
signal and a digital audio signal. In the D/A converter which comes next; these two are converted into two analogue audio channels. 
The analogue signals are fed into separate modulators and then aggregated in the IF (intermediate frequency) position. Then the 
IF filtering takes place, and after that the production in the desired output channel. The fact that mixers are used which can accom-
modate a high output, also fractional N-PLLs, guarantees high-quality transmission. There is a free choice of frequency in the output 
channel from 45 to 862 MHz. On the output side, the modulator does not leak to adjacent channels. If the output level changes, the 
red LED will flash. Every time the level or frequency figures are programmed, automatic measurement of the reference level takes 
place; his function will, however, not start until 100 seconds have elapsed after start-up of the system. When the output load changes 
(perhaps because the output cable is disconnected), a warning and display item for a level fault may also appear. When the fault has 
been identified, the appropriate SNMP Trap message will be sent. Use of this function is optional. By activation of the respective soft-
ware option the services like test lines, the flash of subtitles and BISS decryption can be used.Supported are the BISS mode 1 and 
the BISS mode E with input of the necessary Injected ID, but not the BISS mode E with the additional input of the optional Buried ID.

6. Adjustments

6.1 Adjustment with the Headend Controller

 

·  Adjustment of the addresses at the Bus Extender BEB x00 and at the modules

 

· Activation of the programming mode of each module by selecting the line (BEB x00) and the module position (01... 15) at the

 

  Headend Controller(HCB x00)

 

 

→ 

yellow LED will be lit up til the beginning of the parameter adjustment

 

· Adjustment of the ATB 19x parameter (see chapter 10) 

 green LED is lit up

 

· After the programming the ATB 19x will be automatically switched into the operating

 

 

 yellow LED lights up briefly / green LED is lit up

6.2 Adjustment with the PC / Laptop

 

· Condition for the remote programming is an “online - connection” after IP - standard and an ethernet connection at the PC / Laptop

 

· Adjustment of the line / position addresses at the Bus Extender BEB x00 as well as at the modules

 

· At the Headend Controller HCB x00 IP - address input (e.g. 192.168.001.001)

 

· For “direct connection” between a PC and HCB x00 use a crossed patch cable (RJ 45)

 

· For connection over a deviation use an uncrossed patch cable

 

· HTML - browser start-up and put in IP - address as target address

 

· If connected correctly the HTML - control surface at the PC will open up and a blue LED (LINK) at the HCB x00 will be lit up).

 

· All adjustment of the modules are specified at the control surface.

ASI-TS input port
LED input

ASI-TS output port

LED output

Operating voltage/
control bus

“STANDBY“ LED (red)
“READY“ LED (green)
“ADDR.“ LED (yellow)
Adress selector switch

RF output for TV

Summary of Contents for ATB 19 series

Page 1: ...4 8 Optional hardware variants 4 8 1 IF interface 4 8 2 Additional A V monitor outputs 5 9 Programming by Web server 6 9 1 Main menu 6 9 2 Software options 6 9 3 Loading the programme list 7 9 4 Exten...

Page 2: ...standard B G ATB 191 9848 08 ASI ATV AM A V standard B G ATB 191 9848 09 ASI IFI ATV AM standard B G ATB 192 9848 21 ASI ATV AM standard D K 1 ATB 192 9848 22 ASI ATV AM standard D K 2 ATB 192 9848 24...

Page 3: ...aps because the output cable is disconnected a warning and display item for a level fault may also appear When the fault has been identified the appropriate SNMP Trap message will be sent Use of this...

Page 4: ...flashing error warnings depending on signal ASI without sync e g when there is no input signal service settings are not valid service is decrypted ADDR yellow illuminated or flashing remote control ma...

Page 5: ...input 3 If a module with IF interface is mounted to the wall the usage of SMA angle plugs for the interface side of the connection cable is recommended The cables have to be screwed onto the interfac...

Page 6: ...e code for the language selected Service type shows the type of service selected TV radio Output Frequency table channel selection standard B G channel 2 69 standard D K channel R1 69 Attenuation adju...

Page 7: ...I ATV AM 9 3 Loading the programme list menu 2 This menu contains a list of all services contained in the data stream Language selection can take place here if available Any service is adopted or give...

Page 8: ...will only be available if Subtitling option is on DVB languages index freely selectable 0 255 DVB language code shows the code for the language selected Use extended ID s selection yes no Composition...

Page 9: ...ely selectable 0 16383 Teletext PID freely selectable 0 65535 VBI PID freely selectable 0 65535 Subtitle PID freely selectable 0 65535 Composition Page ID freely selectable 0 65535 Ancillary Page ID f...

Page 10: ...data shows detailed information about current VPS data Current WSS data shows detailed information about current WSS data The following will only be displayed if the test lines option is switched on T...

Page 11: ...ror CRITICAL PLL at output not activated ATB 19x start Edit or Close Power status On Off TV sound Audio gain 6 20 dB Video settings Video output On auto off auto colour palette bar Colour system PAL S...

Page 12: ...al 18 Tonmode Dual invers INFORMATION Sound mode set as dual inverse 12 Block diagram ASI Frontend MPEG decoder Video Audio processing IF RF Vestigial sideband IF modulator 2x FM modulator ASI RF 45 8...

Page 13: ...kHz Output frequency range 45 862 MHz Tuning steps 10 kHz Output level max 116 dB V Range for level adjustment 0 31 5 dB 0 5 dB steps Channel allocation adj channel compatible Connector F socket Impe...

Page 14: ...rogram Clock Reference PDC Program Delivery Control PID Packed Identifier PMT Program Map Table PLL Phase locked loop RF Radio Frequency SECAM S quentiel couleur m moire SNMP Simple Network Management...

Page 15: ...h declares the conformity of the product group Product name ASI Transmodulator Type ATB 19x Product number 9848 xx according to the following regulations EN 50083 2 EN 60728 11 as far as relevant and...

Reviews: