![Blancett B2800 Standard Programming & Installation Manual Download Page 9](http://html.mh-extra.com/html/blancett/b2800-standard/b2800-standard_programming-and-installation-manual_2768503009.webp)
9
store the password and take you back to the RST PSWD
screen.
RST PSWD –
The reset password screen allows the operator
to enter any 4 digit code for the manual reset totals function.
RESET TOTAL –
To reset the monitor total display, in run
mode press the MENU and ENTER simultaneously until TO-
TAL RST starts to flash. The TOTAL RST will stop flashing
and the display will return to the run mode at the conclusion
of the reset procedure.
STORE TOTAL
– The current total can be manually stored
in the monitor’s flash memory. This procedure may be desir-
able prior to replacing the battery. Press and hold the ENTER
key for 2 seconds. The display will respond with a flashing
TOTALSVD and then return to the run mode.
AUTOMATIC STORE TOTAL
– The monitor is equipped
with a store total feature that works automatically, saving the
current total to flash memory. The frequency of saves depends
on the power supply option chosen
Battery Powered: Once per hour and just before a low
battery condition turns the unit off.
Loop Powered: Once every ten minutes.
BATTERY REPLACEMENT
– Battery powered monitors
use a single 1.5V, “D” size, alkaline battery. When replace-
ment is necessary, use a clean fresh battery to insure contin-
ued trouble free operation. It is recommended that the total be
saved to memory before the battery is removed. (See STORE
Note:
This password will allow the operator to manually
reset totals.
Note:
This reset password code will not allow the opera-
tor to enter the programming mode.
Summary of Contents for B2800 Standard
Page 11: ...11 FIGURE 2 CIRCUIT BOARD LAYOUT ...
Page 13: ...13 FIGURE 3 PROGRAMMING MENU ...
Page 16: ...16 ...
Page 19: ...19 NOTES ...