PORTABLE MODEL – U20
Available only in 20 quart size.
1. Store beaters and whips at rear of table top.
2. Lock all 4 casters before using mixer.
3. Refer to General Installation instruction for further
information.
GENERAL FOR ALL MODELS
1.
Electrical Connections
CAUTION:
Before making electrical connections be sure that current and voltage of the
mixer are identical to those of electrical inlet lines.
20 quart, 110 volt mixers are furnished with a six (6) foot flexible power cord.
On 30 quart mixers the line cord is to be supplied by the customer. Connections are made
inside the mixer column through the cover plate located on the back side of the column
near the bottom. NOTE: A six (6) foot flexible three (3) prong cord is available as an extra
cost option.
IMPORTANT: On 3 phase mixers, after electrical connection has been made, be sure the
mixer operates in a counter-clockwise direction as indicated by the arrow located above
the attachment. If electrical connection is reversed the transmission will not shift, nor will
the planetary action function.
2
Transmission Oil
After the first 200 hours of operation and every 6 months thereafter the transmission oil
must be changed.
When adding or changing transmission oil use 50 S.A.E. heavy duty oil. 3 pints required.
-4-
Summary of Contents for B-20
Page 18: ...Transmission Removal and Disassembly 16...
Page 19: ...17...
Page 20: ...18...
Page 21: ...19...
Page 24: ...Parts Section PROTECT YOUR EQUIPMENT USE GENUINE BLAKESLEE PARTS...
Page 25: ...7 28 29 30 31 M 5 3330 D M 5 18769 TRANSMISSION MOTOR AND HOUSING 24...
Page 27: ...MODEL F 30 COLUMN BASE ASSEMBLY 26...
Page 28: ...27...
Page 29: ...28...
Page 30: ...MODELS B 20 F 20 U 20 SERIES COLUMN BASE ASSEMBLY 29...
Page 31: ...30...
Page 32: ...31...
Page 33: ...WIRING DIAGRAM SUPPLY LINE INPUT 3 PHASE 1 PHASE 32...
Page 36: ......
Page 37: ......