ENGLISH
32
5. APPLICATIONS
EVOSTA2, EVOSTA3
series circulators allow integrated adjustment of the differential pressure which enables
the circulator performance to be adapted to the actual requirements of the system. This determines
considerable energy saving, a greater possibility of control of the system, and reduced noise.
EVOSTA2, EVOSTA3
circulators are designed for the circulation of:
–
water in heating and conditioning systems.
–
water in industrial water circuits.
–
domestic water
only for the versions with bronze pump body
.
EVOSTA2, EVOSTA3
circulators are self-protected against:
–
Overloads
–
Lack of phase
–
Excess temperature
–
Over-voltage and under-voltage
6. TECHNICAL DATA
Supply voltage
1x230 V(+/-10%), 50/60 Hz
Absorbed power
See electrical data plate
Maximum current
See electrical data plate
Grade of protection
IPX5
Protection class
F
TF Class
TF 110
Motor protector
No external motor protector is needed
Maximum environment temperature
40 ºC
Liquid temperature
-10 ºC ÷ 110 ºC
Flow rate
See Table 3
Head
See Table 3
Maximum working pressure
1.0 Mpa
– 10 bar
Minimum working pressure
0.1 Mpa
– 1 bar
Lpa [dB(A)]
≤ 43
Table 2: Technical data
Designation index
(example)
EVOSTA
40-70/
130
½”
X
Series name
Maximum head range (dm)
Centre distance (mm)
½” = 1”½ threaded outlets
= 1” threaded outlets
Standard (no ref.)
= 1½” threaded outlets
½”
= 1” threaded outlets
X
= bocche filettate da
2”
Summary of Contents for PREMIUM PLUS WHP030
Page 2: ......
Page 6: ...4 Blade 30 and 40 Water Heater Plus Manual July 2020 3 0 WATER HEATER SCHEMATIC LAYOUT...
Page 7: ...Blade 30 and 40 Water Heater Plus Manual July 2020 5 3 1 SCHEMATIC LEGEND...
Page 18: ...16 Blade 30 and 40 Water Heater Plus Manual July 2020 9 0 MAINTENANCE AND SERVICING CLEARANCES...
Page 19: ...Blade 30 and 40 Water Heater Plus Manual July 2020 17 10 0 FRAME DETAILS...
Page 20: ...18 Blade 30 and 40 Water Heater Plus Manual July 2020 11 0 INSTALLATION SCHEMATIC LAYOUT...
Page 23: ...Blade 30 and 40 Water Heater Plus Manual July 2020 21 14 0 WIRING DIAGRAM...
Page 31: ...Blade 30 and 40 Water Heater Plus Manual July 2020 29 Notes...
Page 32: ...APPENDIX A ALPHA BOILER MANUAL...
Page 91: ...59 Alpha E Tec S 20 30 and 35 Page intentionally Blank...
Page 101: ...Blade 30 and 40 Water Heater Plus Manual July 2020 31 APPENDIX B DAB PUMP MANUAL...
Page 115: ...ENGLISH 41 It is dangerous to touch the circulator DANGER OF SCALDING...
Page 125: ...ENGLISH 51 18 PERFORMANCE CURVES EVOSTA2 40 70 XXX...
Page 126: ...ENGLISH 52 EVOSTA2 80 XXX...
Page 127: ...ENGLISH 53 EVOSTA3 40 XXX...
Page 128: ...ENGLISH 54 EVOSTA3 60 XXX...
Page 129: ...ENGLISH 55 EVOSTA3 80 XXX...