1901-a00
46
S E C T I O N 8
Troubleshooting
SYMPTOM OR PROBLEM: PUMP IS EXCESSIVELY NOISY
Problem Cause(s):
Air in the inlet fluid stream
Relief valve is opening
Pump has decoupled
Pump components are damaged or worn
Pump is cavitating
Discharge line is too restrictive
Cooling path is plugged
Ball bearings are worn or damaged
SYMPTOM OR PROBLEM: PUMP DOES NOT PRIME
Problem Cause(s):
Discharge line is too restrictive
Suction lift is too great
Pump is not wetted
Air leak in the suction line
Pump is running in the wrong direction
Head is positioned incorrectly
Cooling-path plugs are not installed
Pump is locked up with hardened fluid or foreign items
Pump components are damaged or worn
Pump has decoupled
Inner magnets have weakened
Cooling path is plugged
Relief valve is stuck open
SYMPTOM OR PROBLEM: FLOW RATE IS TOO LOW
Problem Cause(s):
Head is positioned incorrectly
Cooling-path plugs are not installed
Discharge line is too restrictive
Viscosity is lower than expected
Air in the inlet fluid stream
Pump is cavitating
Relief valve is opening
Pump components are damaged or worn
Bypass or auxiliary line in the discharge piping is open
Cooling path is plugged
Relief valve is stuck open