37
and 09 is the internal user-
defined EDID®.
EDIDGOUT[xx].
Reads and displays the EDID
of output xx.
xx=01~08, which is the
output port number.
EDIDOUT04:
……
EDIDM[xx]B[yy].
Sets input yy to use the
EDID of output xx.
xx=01~08, where 01~08 is
the output port number.
yy=00~08, where 01~08 is
the input port number and
00 is all inputs.
Input 06 EDID Upgrade OK
By 01 EXT EDID!
/+[xx]/[yy]:zzz.
Send serial data zzz at
speed xx from port yy.
xx=1~7, where 1=2400,
2=4800, 3=9600, 4=19200,
5=38400, 6=57600, and
7=115200.
yy is the output port that
sent the data, with yy=01
meaning local output.
zzz.
EDIDSTA[xx].
Displays the EDID status of
input xx.
xx=00~08, where 01~08 is
the input port number and
00 is all inputs.
Note:
Input 01 EDID From 01
Internal EDID!
Input 02 EDID From 02
Internal EDID!
Input 03 EDID From 03
Internal EDID!
Input 04 EDID From 06
Internal EDID!