• Observe the motor and the hydraulic system for external leaks or abnormal noises
during the commissioning procedure.
• Start the motor break-in. Refer to
on page 67.
Attention:
Do not start the motor, if the air bleeding procedure has not been carried
out.
Stressing an unused motor with full power may cause premature wear or
failure of the motor.
Note:
During all installation and service procedures, plug any open ports and
hoses.
When filling the reservoir, add hydraulic fluid through a filter.
Tightening torques
SCREW / HARDNESS
HUB COVER, f10.9 (Nm)
SHAFT FLANGE, f12.9 (Nm)
M12
110
135
M14
180
215
M16
275
330
M18
383
460
M20
540
650
M22
728
874
The tightening torques are valid for standard and fine thread.
Note:
The maximum torque can be limited at lower value by the motor
attachment.
6.7
Installation Instructions
66
Product Manual