background image

 

 

 

VOE210 Series

 

Multiport Digital VoIP Router

 

Getting Started Guide

 

Important

 

This is a Class A device and is intended for use in a light industrial  environment. It is not intended nor approved for use in an industrial  
or residential environment.

CUSTOMER

SUPPORT

INFORMATION

Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA  15055-1018
Web site: www.blackbox.com • E-mail: [email protected]

Summary of Contents for VOE210 Series

Page 1: ...pproved for use in an industrial or residential environment CUSTOMER SUPPORT INFORMATION Order toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX FREE technical support 24 hour...

Page 2: ...can be determined by disconnecting the cables try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving...

Page 3: ...peraci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el...

Page 4: ...a cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado o B Objectos han ca do o l quido ha sido derramado...

Page 5: ...ts 1 General information 15 2 Applications overview 21 3 VOE210 installation 24 4 Initial configuration 29 A Specifications 38 B Cabling 43 C Port pin outs 47 D VOE210 factory configuration 51 E End u...

Page 6: ...ligence of enterprise communication 22 Application Multi service ISDN Internet telephony IAD 23 3 VOE210 installation 24 Planning the installation 25 Site log 25 Network information 25 Network Diagram...

Page 7: ...l link 37 A Specifications 38 DSP 39 Voice connectivity 39 Data connectivity 39 Voice processing signalling dependent 39 Fax and modem support 40 Voice signalling 40 Voice routing session router 40 IP...

Page 8: ...8 VOE21x Getting Started Guide Table of Contents 5 Warranty 54 6 Termination 55 7 Other licenses 55...

Page 9: ...nication application 22 5 Internet telephony IAD application 23 6 Power LED 28 7 Connecting the VOE210 to your laptop PC 30 8 Connecting the VOE210 to the network 33 9 Connecting a serial terminal 44...

Page 10: ...General conventions 14 2 Rear panel ports 17 3 VOE210 LED definitions 20 4 Sample site log entries 25 5 Factory default IP address and network mask configuration 31 6 RJ 45 socket 48 7 RJ 45 socket 4...

Page 11: ...applications Chapter 3 on page 24 provides hardware installation procedures Chapter 4 on page 29 provides quick start procedures for configuring the VOE210 router Appendix A on page 38 contains speci...

Page 12: ...calls attention to important information The alert symbol and CAUTION heading indicate a potential haz ard Strictly follow the instructions to avoid property damage The shock hazard symbol and CAUTION...

Page 13: ...or systems without a power switch line voltages are present within the power supply when the power cords are connected The wall outlet that is utilized to power the VOE210 router shall be within 10 fe...

Page 14: ...nt Futura bold italic type Parts of commands which are related to elements already named by the user are in boldface italic font Italicized Futura type Variables for which you supply values are in ita...

Page 15: ...15 Chapter 1 General information Chapter contents VOE210 overview 16 VOE210 rear panel 17 VOE210 front panel 19...

Page 16: ...Router performs the following major functions Eight channels of Voice over IP and local voice switching via 5 ISDN BRI S0 ports Each port can be switched between NT and TE per software One port can b...

Page 17: ...gure 2 connect the unit to an Ethernet LAN for example a PC printer or wireless bridge BRI 0 0 ISDN BRI TE NT port RJ 45 socket S0 S T interface see figure 2 connects the VOE210 with an ISDN device ov...

Page 18: ...phones with power BRI 0 4 VOE212 only ISDN BRI NT TE port RJ 45 socket S0 S T interface see figure 2 connects the VOE210 with an ISDN device over an S T bus e g a PBX or an NT The port can be switche...

Page 19: ...listed in table 3 on page 20 Multiport Digital VoIP Router Power Run VoIP Link ENET 0 Act Link ENET 0 100 ENET 0 Act Link ENET 0 100 BRI 0 Active BRI 0 Link BRI 1 Link BRI 3 Active BRI 3 Link BRI 4 Li...

Page 20: ...ff indicates the unit is not configured or registered or has no active direct routed VoIP connection Flashing green indicates that the unit is attempting to register or has failed to register BRI Link...

Page 21: ...21 Chapter 2 Applications overview Chapter contents Introduction 22 Application Edge intelligence of enterprise communication 22 Application Multi service ISDN Internet telephony IAD 23...

Page 22: ...ollowing reasons Bypassing the PSTN Using Internet telephony service providers ITSPs instead of incumbent carriers dra matically reduces telephony costs IP PBXs with their full suite of features and e...

Page 23: ...on the PBXs 5 Once the IP PBX is ready you can choose on incoming calls from the PSTN for each extension whether this extension is to be directed to the IP PBX or on the legacy PBX Application Multi...

Page 24: ...ormation 26 Software tools 27 Power source 27 Location and mounting requirements 27 Installing the gateway router 27 Placing the VOE210 27 Installing cables 27 Connecting ISDN terminals and NT to the...

Page 25: ...as listed in table 4 Network information Network connection considerations that you should take into account for planning are provided for several types of network interfaces are described in the foll...

Page 26: ...ting requirements The VOE210 router is intended to be placed on a desktop or similar sturdy flat surface that offers easy access to the cables Allow sufficient space at the rear of the chassis for cab...

Page 27: ...r details on the BRI port pinout and ISDN cables refer to Appendix B Cabling on page 43 and Appendix C Port pin outs on page 47 Connecting the 10 100Base T Ethernet LAN and WAN cables The VOE210 has a...

Page 28: ...wer LED 4 Verify that the green Power LED is lit see figure 6 Internal S Bus power supply The Model VOE210 supplies S Bus line power on the BRI ports that can be activated individually for each port I...

Page 29: ...32 Factory default IP settings 32 Login 32 Changing the WAN IP address 32 3 Connecting the VOE210 to the network 33 4 Loading the configuration optional 34 Bootloader 35 Start Bootloader 35 Start up...

Page 30: ...r the VOE210 device 1 Connecting the VOE210 to your laptop PC First the VOE210 must be connected to the mains power supply with the power cable Wait until the Power LED stops blinking and stays lit co...

Page 31: ...VOE210 to the net work on page 32 Otherwise refer to the following sections to change the addresses and network masks Login To access the VOE210 start the Telnet application Type the default IP addre...

Page 32: ...rt up the system will initialize itself using the modified configuration 172 16 1 99 if ip eth0 copy running config startup config 172 16 1 99 if ip eth0 The VOE210 can now be connected to your networ...

Page 33: ...ring the VOE210 Simply download the configuration note that matches your application to your PC Adapt the con figuration as described in the configuration note to your network remember to modify the I...

Page 34: ...ng application images e g VOE Firmware via the serial link of the console Start Bootloader To start the Bootloader power on the VOE210 while pressing the reset button Open a Telnet session to the VOE2...

Page 35: ...receive the new application image mask_len is the length of the network address or the number of 1 s within the subnet mask See Note below 2 optional RedBoot ip_address g gateway Sets the IP address o...

Page 36: ...RedBoot ip l 172 16 40 98 19 RedBoot ip g 172 16 32 1 RedBoot ping h 172 16 32 100 Network PING from 172 16 40 98 to 172 16 32 100 PING received 10 of 10 expected RedBoot load r v h 172 16 32 100 b 0...

Page 37: ...dem or ymodem Specify the protocol to be used X Modem or Y Modem base_address memory location where to store the application image Use the default address 0x1800100 Execute the above RedBoot command f...

Page 38: ...pter contents DSP 40 Voice connectivity 40 Data connectivity 40 Voice processing signalling dependent 40 Fax and modem support 41 Voice signalling 41 Voice routing session router 41 IP services 42 Man...

Page 39: ...ctivity Two 10 100Base TX Ethernet ports All ports full duplex autosensing auto MDX Voice processing signalling dependent Four or eight full duplex channels with Voice CODECS G 711 A Law Law 64 kbps G...

Page 40: ...in band out of band Configurable progress tones Voice routing session router Local switching hairpinning Least cost routing Interface huntgroups Call Distribution groups Number blocking Call Routing C...

Page 41: ...encryption with the VOE210 you may need to purchase additional license keys Management Web based GUI Industry standard CLI with local console RJ 45 RJ 232 9600 bps 8 N 1 and remote Telnet access fully...

Page 42: ...Physical 42 VOE21x Getting Started Guide A Specifications Operating humidity up to 90 non condensing...

Page 43: ...43 Appendix B Cabling Chapter contents Introduction 45 Console 45 Ethernet 46 ISDN BRI 47...

Page 44: ...picted in figure 9 Figure 9 Connecting a serial terminal Note See section Console port on page 48 for console port pin outs The interconnecting cables shall be acceptable for external use and shall be...

Page 45: ...hernet straight through cable diagram The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age current anticipated tempera...

Page 46: ...Connecting an ISDN device The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age current anticipated temperature flamma...

Page 47: ...47 Appendix C Port pin outs Chapter contents Introduction 49 Console port 49 Ethernet 49 ISDN BRI 0 0 NT Net or TE User port 50 ISDN BRI 0 1 0 3 TE Usr or NT Net 50...

Page 48: ...onfiguration settings 9600 bps 8 bits no parity 1 stop bit no flow control Figure 12 EIA 561 RJ 45 8 pin port Note N C means no internal electrical connection Ethernet Note Pins not listed are not use...

Page 49: ...ugh to the Phone port at all times and independent of the fallback relay s status Note On each ISDN BRI port in TE mode it is possible to switch on ISDN line power per software The total amount of pow...

Page 50: ...ISDN BRI 0 1 0 3 TE Usr or NT Net 50 VOE21x Getting Started Guide C Port pin outs...

Page 51: ...51 Appendix D VOE210 factory configuration Chapter contents Introduction 52...

Page 52: ...dhcp server DHCP network 192 168 1 0 255 255 255 0 include 192 168 1 10 192 168 1 19 lease 2 hours default router 192 168 1 1 context ip router interface eth0 ipaddress 172 16 40 1 255 255 0 0 use pr...

Page 53: ...53 Appendix E End user license agreement Chapter contents End User License Agreement 54 1 Definitions 54 2 Title 54 3 Term 54 4 Grant of License 54 5 Warranty 54 6 Termination 55 7 Other licenses 55...

Page 54: ...nated Equipment at a site owned or leased by the End User B The End User may copy licensed Program s as necessary for backup purposes only for use with the Des ignated Equipment that was first purchas...

Page 55: ...ate this Agreement should End User violate any of the provisions of section 4 Grant of License on page 54 C Upon termination for A or B above or the end of the Term End User is required to destroy all...

Reviews: