CHAPTER 3: Installation
b) Insert the console drawer’s two sliding rails into the tight space formed by the rear brackets and the
extensions. With both hands, push in the KVM module
evenly
on the right and left sides.
8. Push the rear brackets all the way in and fasten them.
9. Slide out the console drawer. Push the KVM module evenly toward the drawer and secure both units using
the attached thumbscrews. See Figure 3-7.
Figure 3-7. Securing the KVM module to the console drawer.
10. Make sure the Centronics connectors on the KVM module and attached cable are firmly mated. See
Figure 3-8.
Figure 3-8. Centronics connectors.
11. Connect the power supply to the barrel connector on the KVM module.
12. For operation, pull out the drawer from the 4-post rack or cabinet and latch it in the extended position. A
locking mechanism locks the drawer when it’s pulled out, pushed in, or folded down. When not in use,
push in the drawer, then fold down, lock, and secure the display.
Console drawer
KVM module
Thumbscrews
(permanently
attached to the tray)