724-746-5500 | blackbox.com
Page 15
Chapter 4: Enhanced Operation
4. Enhanced Operation
Via an OSD in the Remote Unit, the ACX310F enables the following configuration
options:
1. Updating the Extender.
2. Set Backlight.
3. Locking OSD.
4. Enabling/disabling Monitor Sync.
5. DDC options.
Entering the OSD
To enter the Extenders OSD, press the ScrollLock key on the attached keyboard five
times quickly.
The OSD menu appears on the remote unit’s attached display (see Figure 4-1).
Figure 4-1. OSD menu.
NOTE: If the OSD is locked via Option L, the OSD is only available for the first
10 minutes after power up.
U =Update Flash FW
To update the extender’s firmware, you will need to open a graphic file (update file)
on the target device, and then enter the command “U” and wait for the update to
be performed.