2.4 Hardware Description

2.4.1 Transmitter (Local Unit)

Front Panel

The transmitter‘s (ACX310F or ACX310FIA) front panel is blank except for a Power 

Status LED, which is described in Table 2-1.

Back Panel

The transmitter’s (ACX310F or ACX310FIA) back panel is shown in Figures 2-1 and 

2-2. Table 2-1 describes its components.

 

3                 4          5            6

2

 

Figure 2-1. ACX310F transmitter’s back panel. 

 

3                 4          5            6

  2 

                7          7

 

Figure 2-2. ACX310FIA transmitter’s back panel.

Summary of Contents for ServSwitch ACX310F

Page 1: ... Extender EC ACX310F ACX310FIA Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Customer Support Information ...

Page 2: ...uble Diamond logo are registered trademarks and ServSwitch is a trademark of BB Technologies Inc HDMI is a registered trademark of HDMI Licensing L L C Windows is a registered trademark of Microsoft Corporation Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 3: ... to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le présent a...

Page 4: ...bra o superficie similar puede bloquea la ventilación no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuent...

Page 5: ...o sean derramados sobre la cubierta u orificios de ventilación 18 Servicio por personal calificado deberá ser provisto cuando A El cable de poder o el contacto ha sido dañado u B Objectos han caído o líquido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempeño o E El aparato ha sido tirado o...

Page 6: ...at s Included 9 2 4 Hardware Description 10 2 4 1 Transmitter Local Unit 10 2 4 2 Receiver Remote Unit 12 3 Installation and Operation 14 3 1 Cable Requirements 14 3 2 Installing the Transmitter and the Receiver 14 3 3 Initial Operation 14 4 Enhanced Operation 15 5 Troubleshooting 18 5 1 Contacting Black Box 18 5 2 Shipping and Packaging 18 ...

Page 7: ...d DVI video USB Connectors ACX310F Transmitter 1 DVI I input physical connector supports DVI D only 1 DVI I output physical connector supports DVI D only 1 USB Type B F 1 SFP cage LC connectors multimode 1 barrel connector for power ACX310FIA Transmitter also includes 2 3 5 mm bidirectional audio connectors ACX310F Receiver 1 DVI I output physical connector supports DVI D only 4 USB Type A F 1 SFP...

Page 8: ...erating 32 to 113 F 0 to 45 C Storage 4 to 158 F 20 to 70 C Operating Humidity 80 noncondensing Altitude 10 000 feet maximum Power External in line power supply Input 100 240 VAC 50 60 Hz 0 5 A Output 12 VDC 1 A 12 W Power supply cord length 5 ft 1 5 m Dimensions Each unit Transmitter or Receiver 1 6 H x 3 85 W x 4 17 D 4 1 x 9 8 x 10 6 cm Weight Each unit 0 61 lb 0 27 kg Total 1 22 lb 0 55 kg ...

Page 9: ... 5 µm duplex fiber optic cable Provides local monitoring Supports USB 2 0 extension Plug and play installation with DDC EDID reading An optional mounting option for 19 racks with four units in 1 rack unit RU is available Can also be wall table or DIN rail mounted Mounting options accessories are ACX300 RMK 19 Rackmounting Kit for up to 4 local or remote units ACX300 TMK Table and Wallmount Kit for...

Page 10: ... Local Unit Front Panel The transmitter s ACX310F or ACX310FIA front panel is blank except for a Power Status LED which is described in Table 2 1 Back Panel The transmitter s ACX310F or ACX310FIA back panel is shown in Figures 2 1 and 2 2 Table 2 1 describes its components 3 4 5 6 2 Figure 2 1 ACX310F transmitter s back panel 3 4 5 6 2 7 7 Figure 2 2 ACX310FIA transmitter s back panel ...

Page 11: ...en power to the transmitter is on 2 1 DVI connector Connects to the PC 3 1 DVI connector Connects to a local monitor 4 1 barrel connector Links to 12 VAC 1 A power 5 1 USB Type B connector Links to USB port on the PC 6 1 SFP module cage for multimode fiber connector Connects one end of the 1640 foot 500 m link between the transmitter and receiver 7 2 3 5 mm connectors Links to audio in and audio o...

Page 12: ...er s front panel is blank except for a Power Status LED which is described in Table 2 2 Back Panel The receiver s back panel is shown in Figures 2 3 and 2 4 Table 2 2 describes its components 2 3 3 5 3 4 Figure 2 3 ACX310F receiver s back panel 2 3 3 5 6 6 3 4 Figure 2 4 ACX310FIA receiver s back panel ...

Page 13: ...hts when power to the receiver is on 2 1 DVI connector Connects to DVI monitor 3 4 USB Type A connectors Link to keyboard mouse and two USB peripheral devices 4 1 barrel connector Links to 12 VAC 1 A power 5 1 SFP module cage for multimode fiber connector Connects one end of the 1640 foot 500 m link between the receiver and transmitter 6 2 3 5 mm connectors Links to audio in and audio out ...

Page 14: ... and play Simply plug in the following connections as shown in Figure 3 1 DVI Monitor PC Transmitter Local Unit DVI DVI Monitor Mouse Keyboard Receiver Remote Unit 62 5 µm duplex fiber optic cable Figure 3 1 Connecting the extender units 3 3 Initial Operation Switch on the device Both extenders start working automatically For about five seconds the LED will blink red When the LED turns green the d...

Page 15: ...SD To enter the Extenders OSD press the ScrollLock key on the attached keyboard five times quickly The OSD menu appears on the remote unit s attached display see Figure 4 1 Figure 4 1 OSD menu NOTE If the OSD is locked via Option L the OSD is only available for the first 10 minutes after power up U Update Flash FW To update the extender s firmware you will need to open a graphic file update file o...

Page 16: ...Backlight Enter 0 9 Figure 4 2 USB high speed memory option L Lock Menu enabled disabled Once enabled you can only enter the OSD during the first 10 minutes after the remote unit powers up It will be locked afterwards Figure 4 3 Lock menu The default setting is disabled ...

Page 17: ...eactivate the monitor synchronization If enabled the graphics card refresh rates are synchronized with the Rx attached monitors This will optimize motion picture content applications but might not work properly with all monitors flicker may occur The default setting is disabled Figure 4 4 Monitor sync disabled screen ...

Page 18: ...you do make a record of the history of the problem We will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse 5 2 Shipping and Packaging If you need to trans...

Page 19: ...1 256 98 56 43 1 256 98 56 Belgium www blackbox be support nederlands blackbox be support french blackbox be support english blackbox be 32 2 725 85 50 32 2 725 92 12 Denmark www blackbox dk support blackbox dk 45 56 63 30 10 45 56 65 08 05 Finland www blackbox fi tuki blackbox fi 358 201 888 800 358 201 888 808 France www blackbox fr tech blackbox fr 33 1 45 606 717 33 1 45 606 747 Germany www bl...

Page 20: ...241 7799 31 30 241 4746 Norway www blackbox norge no support blackboxnorge no 47 55 300 710 47 55 300 701 Spain www blackbox es tecnico blackbox es 34 9162590732 34 916239784 Sweden www blackboxab se support blackboxab se 46 8 44 55 890 46 08 38 04 30 Switzerland www black box ch support black box ch 41 55 451 70 71 41 55 451 70 75 UK www blackbox co uk techhelp blackbox co uk 44 118 965 6000 44 1...

Page 21: ...724 746 5500 blackbox com Page 21 NOTES ...

Page 22: ...724 746 5500 blackbox com Page 22 NOTES ...

Page 23: ...724 746 5500 blackbox com Page 23 NOTES ...

Page 24: ...ould be ACX310F version 1 About Black Box Black Box provides an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech Support available in 30 seconds or less Copyright 2013 Black Box Corporation All rights reserved ...

Reviews: