Specifications
MicroRACK
Compliance:
CE; FCC Part 15, Class A
Connectors:
(6) card-edge contacts
for each of (17) card slots (male
toward front cards, female toward
rear cards), plus (2) sets of (10)
female card-edge contacts for
power supplies
Operating Temperature Tolerance:
32 to 122°F (0 to 50°C)
Humidity Tolerance:
Up to 90%
noncondensing
Power:
From one or two cardmount
power supplies, either AC or DC
input (comes with one supply
installed)
Size:
3.5"H (3U) x 19"W x 7.25"D
(8.9 x 48.3 x 18.4 cm)
Weight:
6.6 lb. (3 kg)
Power Supplies
PS466A, PS466A-DC
Compliance:
Both: CE; FCC Part 15
Subpart B Class A, IC Class/
classe A;
PS466A: NRTL, UL
®/
1950, CSA 950,
EN 60950
Input:
PS466A: 90–264 VAC (115 or
230 VAC nominal), 47–63 Hz;
PS466A-DC: -42 to -60 VDC
(-48 VDC nominal)
Output:
To midplane bus at 75%
voltage: 12.3 to 12.5 VDC (12.4 VDC
nominal); Power: 72 watts,
continuous; efficiency (at full load,
with 115-VAC input for PS466A or
-48-VDC input for PS466A-DC): 78%
minimum, 88% maximum
modem cable for connecting the
terminal to the card. Also be sure to
have a 10BASE-T connection from
your local LAN, a locally connected
workstation that you can use to
ping and HTTP into the card, and an
IP address for the card. In addition,
you’ll need the network’s space and
submask and the IP address for the
default gateway of your LAN.
Control Module
This Control Modules enable
you to daisychain up to eight
16-Port Managed MicroRACKs
and control them all.
With a Control Module installed
in each of the racks, you have total
control of up to 120 installed DSL
modem, line driver, or fiber modem
or CSU/DSU cards! What’s more,
you can manage the 120 remote
modem/line drivers as well.
Installed in the 16-Port
Managed MicroRACK, the module
is used to control the rack’s other
cards from an asynchronous
RS-232 terminal or a computer
running terminal emulation.
Supporting terminal data rates to
19.2 kbps, the Control Module has a
modular port for connection to the
RS-232 terminal, and a serial port for
daisychaining between racks.
When you want to reach or
configure a particular function card,
simply key in an addressable
command, which the Control
Module passes along to all the
function cards in the rack. The
appropriate card recognizes its
address and responds to the
command.
As with the 16-Port Managed
MicroRACK’s function cards, the
Control Module consists of a front
card and a rear card that meet in
the middle of the rack. The rear
card has two modular 10-pin RJ
jacks (labeled Port A1) for
connection to the RS-232 terminal.
If the Control Module is being used
in a daisychained application, the
module’s
Port B1
provides the link
to the next Control Module in the
chain.
Wiring a local Control Module
for a daisychain connection
requires the use of two straight-
through modular cables. One cable
connects the serial port of the
RS-232 terminal to Port A1 of the
chain’s first Control Module; and the
second connects Port B1 of the
chain’s first module to Port A1 of the
chain’s second module. You would
use the same cabling procedure to
connect the second module to a
third module, and so on if there are
additional modules in the chain.
(continued from page 3)
User Controls:
(1) midplane-mounted
jumper to select maintenance mode
(no alarm if power supply is
removed)
Connectors:
PS466A: (1) IEC-320, 3-pin
alarm; PS466A-DC: (3) screw
terminals, 3-pin alarm
Indicators:
(3) LEDs for normal
operation, power failure, excessive
internal temperatures
Temperature Tolerance:
Operating:
32 to 122°F (0 to 50°C) at up to 100%
load; above 122˚F (50˚C), load
capacity is derated linearly by 2.5%
for each 1.8˚F until a maximum
temperature of 158˚F (70˚C) is
reached at up to 50% load
Humidity Tolerance:
Up to 90%
noncondensing
Size:
Front card: 3.3"H x 1.5"W x 5"D
(8.4 x 3.8 x 12.7 cm);
Rear card: 3.3"H x 1.5"W x 2.25"D
(8.4 x 3.8 x 5.7 cm)
SNMP/HTTP Card
Compliance:
CE; FCC Part 15 Subpart
B Class A, IC Class/classe
Standard:
IEEE 802.3 Ethernet v2
Interfaces:
10BASE-T; EIA/TIA RS-232,
DTE; proprietary Managed
MicroRACK power and data bus
Transmission Format:
RS-232:
Asynchronous
Data Format:
RS-232: 8 data bits, no
parity, 1 stop bit (fixed)
Data Rate:
10BASE-T: 10 Mbps;
RS-232: 19,200 bps (fixed)
Flow Control:
RS-232: Responds to
CTS (hardware) flow control only
Maximum Distance:
10BASE-T:
328 ft. (100 m) to next device;
RS-232: 50 ft. (15.2 m) to next
device
User Controls:
RS-232 terminal
session console (requires VT100
™
or compatible terminal emulation);
internal HTML management pages
accessible through Ethernet
network
Indicators:
(9) LEDs: Power, (2) TD
(Transmit Data), (2) RD (Receive
Data), LI (Link Integrity), PPP (
not
supported at this time
), Poll (poll
signal), Fault (Fault Detection)
Connectors:
(1) RJ-45 female for
10BASE-T; (1) DB25 female for
RS-232; 50-pin card-edge on both
front and rear cards
Power:
From one or two cardmount
power supplies, either AC or DC
input (comes with one supply
installed)
Temperature Tolerance:
Operating:
32 to 122˚F (0 to 50˚C)
Humidity Tolerance:
5 to 95%
noncondensing
Size:
Front card: 3.3"H x 1.5"W x 5"D
(8.4 x 3.8 x 12.7 cm);
Rear card: 3.3"H x 1.5"W x 2.25"D
(8.4 x 3.8 x 5.7 cm)
Control Module
Compliance:
CE; FCC Part 15 Subpart
B Class A, IC Class/classe A
Interfaces:
EIA/TIA RS-232,
proprietarily pinned on 10-pin RJ
connectors in a manner similar to
EIA/TIA-561; port A1 is DCE, port B1
is DTE; proprietary Managed
MicroRACK power and data bus
Transmission Format:
Asynchronous
Data Format:
Transparent to data
format (data bits, stop bits, and
parity)
Data Rate:
Transparent to data rates
up to 19.2 kbps
Flow Control:
Transparent to
software flow control; RS-232
hardware flow-control leads are
always ON (for continuous
transmission)
User Controls:
(5) rear-card jumpers:
(1) for signal ground/frame ground
connection or isolation; (4) not used
Indicators:
(5) LEDs: Power, (2) TD
(Transmit Data), (2) RD (Receive
Data)
Connectors:
(2) 10-pin RJ female:
(1) for output to terminal or another
module (Port A1, DCE); (1) for input
from another module (Port B1, DTE)
Power:
From one or two cardmount
power supplies, either AC or DC
input (comes with one supply
installed)
Operating Temperature Tolerance:
32 to 122˚F (0 to 50˚C)
Humidity Tolerance:
Up to 95%
noncondensing
Size:
Front card: 3.3"H x 1.5"W x 5"D
(8.4 x 3.8 x 12.7 cm);
Rear card: 3.3"H x 1.5"W x 2.25"D
(8.4 x 3.8 x 5.7 cm)