background image

Serial Data Buffer

Page 12

FCC Statement of Compliance

This  equipm ent gene rates, uses, an d can rad iate radio freq uency  energy  and if  not
installed and used properly, that is, in strict accordance with the manufacturer’s
instructions, may ca use interfer ence to ra dio com munic ation.  It has been tested and
found to comply w ith the limits for a Class  A comp uting dev ice in acco rdance w ith
the specification s in Subp art B of P art 15 of F CC ru les, which  are design ed to
provide reasonable prote ction aga inst such inte rference  when th e equipm ent is

operated in a comm ercia l environment.  Operation of this equipment in a
residential area is likely to cause interference, in which case the user at his own
expense  will be required to take whatever measures may be necessary to correct the
interference.

Changes or modifications not expressly approved by the party responsible for
comp liance cou ld void th e user’s au thority to o perate the  equipm ent.

Summary of Contents for PI1375A

Page 1: ...r toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX SUPPORT FREE technical support 24 hours a day 7 days a week Call724 746 5500 or fax 724 746 0746 INFORMATION Mail order Bla...

Page 2: ...s PI140xA 4 Operation 5 Controls and Indicators 5 Reset Button 5 Copy Button 5 Data In Out LEDs 5 Flow Control 6 Hardware Flow Control 6 Software Flow Control 6 Self Test 6 Sample Self Test Output 7 E...

Page 3: ...ectional d ata communications through buffering and user selectable hardware or software flow control The large primary buffer is associated exclusively with the Input port however Each model SerialDa...

Page 4: ...e R S232 standard The input port functions as a DTE type device w hereas the output port functions as a DCE type device Both input and output connectors are DB25F Black Box offersmany cable options fo...

Page 5: ...9600 9600 C 9600 4800 C 9600 2400 C 9600 1200 C 19 2K 9600 C 19 2K 4800 C 19 2K 2400 C 19 2K 1200 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0...

Page 6: ...6K 38 4K C 57 6K 19 2K C 57 6K 9600 C C 115 2K 115 2K C 115 2K 57 6K C 115 2K 38 4K C 115 2K 19 2K C 115 2K 9600 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0...

Page 7: ...w buffer is full Controls and Indicators Reset Button The Reset bu tton is used to reset the Data Buffer to initialize memory to re read the dipsw itches to ena ble the copy featur e or to initiate th...

Page 8: ...CTS thereby signaling to the output device to stop sending data When the accumulated data has been successfully transmitted to the host DSR and CT S will be restored Software Flow Control The Data Bu...

Page 9: ...8 Parity none Testing SRAM 64K Blocks Writing Block 0 Writing Block 1 Verifying Data Reading Block 0 OK Reading Block 1 OK NOTE The next part of th e test is optional User ca n press R eset to abo rt...

Page 10: ...esent 3 Off 128K On 512K 4 Third Module Off Present On Not Present 5 Off 128K On 512K 6 Fourth Module Off Present On Not Present 7 Off 128K On 512K 8 Not Used Cabling Black Box offers many cable optio...

Page 11: ...ncluding C the nature and duration of the problem C when the p roblem oc curs C the equipment involved in the problem C any particular application that when used appears to create the problem or make...

Page 12: ...ect not used 20 DTR Data Term Ready Tied to RTS used for hardware flow Output Port Pinouts DCE Pin Signal Description Comment 1 Ch Gnd Chassis Ground not used 2 RXD Receive Data Input from attached Ou...

Page 13: ...x up to 2MB total Used in any combination Indicators Green LEDs for DC Power Data In and Data Out Red LED for Pause Status Controls Push button momentary contact Reset and Copy Push button alternate a...

Page 14: ...co rdance w ith the specification s in Subp art B of Part 15 of F CC ru les which are design ed to provide reasonable protection against such inte rference when th e equipm ent is operated in a comm e...

Page 15: ...no debe intentardar servicio alequipo el ctrico m s all a lo descrito en las instruc ciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico...

Page 16: ...l cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser to mado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servic...

Page 17: ...Serial Data Buffer Page 15 NOTES...

Page 18: ...Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 146 0746...