background image

Serial Data Buffer

Page 8

Expansion Memory

The Data B uffer has fo ur 40-p in heade rs inside the e nclosure  to accom moda te
memory  modu les of either 1 28K o r 512K  mem ory in  any combination.  Expansion
modules can be separately purchased and are user-installable.  Memory modules
must  be installed in  consecu tive positio ns from left to right.  An 8-position
dipswitch inside the enclosure,  labeled “

SW2 - Memory Config,

” is used to set the

memory  configuration.  These switches must be set any time  the mem ory cap acity
has chan ged.  

The switches are  set as follows:

<

– OFF   ON –>

1

First Module   - Off = 128K;     On = 512K

2

Second Module  - Off = Present;  On = Not Present

3

- Off = 128K;     On = 512K 

4

Third Module   - Off = Present;  On = Not Present

5

- Off = 128K;     On = 512K

6

Fourth Module  - Off = Present;  On = Not Present

7

- Off = 128K;

   On = 512K

8

Not Used

Cabling

Black Box offers many cable options for use with its serial Data Buffer
products.  The following represent the most commonly used:

C

For connection with a Personal Computer serial port (i.e. COMx) as the
input device (DTE to DTE) - order product code EVMBPC.

C

For connection with a Personal Computer serial port (i.e. COMx) as the
output device (DCE to DTE) - order product code EVMBMC.

C

For connection with a serial printer as the output device with DB25F
connector (DCE to DTE) - order product code ECM12C.

C

For connection with a mod em as the output device (DC E to DCE) -
order product code EYN255.

C

For connection with a mod em as the input device (DCE  to DTE) -
order product code ECM12C.

Summary of Contents for PI1375A

Page 1: ...r toll free in the U S 24 hours 7 A M Monday to midnight Friday 877 877 BBOX SUPPORT FREE technical support 24 hours a day 7 days a week Call724 746 5500 or fax 724 746 0746 INFORMATION Mail order Bla...

Page 2: ...s PI140xA 4 Operation 5 Controls and Indicators 5 Reset Button 5 Copy Button 5 Data In Out LEDs 5 Flow Control 6 Hardware Flow Control 6 Software Flow Control 6 Self Test 6 Sample Self Test Output 7 E...

Page 3: ...ectional d ata communications through buffering and user selectable hardware or software flow control The large primary buffer is associated exclusively with the Input port however Each model SerialDa...

Page 4: ...e R S232 standard The input port functions as a DTE type device w hereas the output port functions as a DCE type device Both input and output connectors are DB25F Black Box offersmany cable options fo...

Page 5: ...9600 9600 C 9600 4800 C 9600 2400 C 9600 1200 C 19 2K 9600 C 19 2K 4800 C 19 2K 2400 C 19 2K 1200 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0...

Page 6: ...6K 38 4K C 57 6K 19 2K C 57 6K 9600 C C 115 2K 115 2K C 115 2K 57 6K C 115 2K 38 4K C 115 2K 19 2K C 115 2K 9600 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0...

Page 7: ...w buffer is full Controls and Indicators Reset Button The Reset bu tton is used to reset the Data Buffer to initialize memory to re read the dipsw itches to ena ble the copy featur e or to initiate th...

Page 8: ...CTS thereby signaling to the output device to stop sending data When the accumulated data has been successfully transmitted to the host DSR and CT S will be restored Software Flow Control The Data Bu...

Page 9: ...8 Parity none Testing SRAM 64K Blocks Writing Block 0 Writing Block 1 Verifying Data Reading Block 0 OK Reading Block 1 OK NOTE The next part of th e test is optional User ca n press R eset to abo rt...

Page 10: ...esent 3 Off 128K On 512K 4 Third Module Off Present On Not Present 5 Off 128K On 512K 6 Fourth Module Off Present On Not Present 7 Off 128K On 512K 8 Not Used Cabling Black Box offers many cable optio...

Page 11: ...ncluding C the nature and duration of the problem C when the p roblem oc curs C the equipment involved in the problem C any particular application that when used appears to create the problem or make...

Page 12: ...ect not used 20 DTR Data Term Ready Tied to RTS used for hardware flow Output Port Pinouts DCE Pin Signal Description Comment 1 Ch Gnd Chassis Ground not used 2 RXD Receive Data Input from attached Ou...

Page 13: ...x up to 2MB total Used in any combination Indicators Green LEDs for DC Power Data In and Data Out Red LED for Pause Status Controls Push button momentary contact Reset and Copy Push button alternate a...

Page 14: ...co rdance w ith the specification s in Subp art B of Part 15 of F CC ru les which are design ed to provide reasonable protection against such inte rference when th e equipm ent is operated in a comm e...

Page 15: ...no debe intentardar servicio alequipo el ctrico m s all a lo descrito en las instruc ciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico...

Page 16: ...l cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser to mado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servic...

Page 17: ...Serial Data Buffer Page 15 NOTES...

Page 18: ...Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 146 0746...

Reviews: