20
SFOM-HS2
3. Carefully close the two halves of the unit’s
plastic case, pressing them together firmly
until the four locking tabs snap back into place.
4. If possible, plug the SFOM-HS2 directly into
your DTE’s DB25 connector (or, if your unit is
a V.35 model, run the included adapter cable
from the SFOM-HS2 to your DTE’s M/34 [also
called “34-pin M-block”] connector). If you have
to run an additional cable between the DTE
and the SFOM-HS2, keep it as short as possible.
Once you’ve made this connection, tighten the
connector screws to ensure a secure hold.
5. Remove the plastic dust caps from the
fiberoptic connectors and attach your
fiber cable to them:
• Connect the local SFOM-HS2’s TX port
to the remote unit’s RX port.
• Connect the local SFOM-HS2’s RX port
to the remote unit’s TX port.
Summary of Contents for MT632A-SM23
Page 27: ...NOTES...