VDSL Point to Point Solution (MEG101AE-R2) 

 
MEG101AE-R2 works as transparent Ethernet and/or telephony point to point 
bridge. MEG101AE-R2 uses QAM-based 4-band VDSL technologies, which 
supports max distances: 
1.9Km(6333ft) at 5M/5M 
1.3Km(4333ft) at 15M/15M 
800m(2666ft) at 25M/25M 
 
 
The front-panel provides LED indications of system and interface status. The 
built-in POTS splitter allows a standard POTS phone to be connected. Full or 
half-duplex mode of LAN operations is automatically sensed and configured. 
VDSL link rates are configured by local Modem automatically 

MEG101AE-R2 supports auto-speed and plug & play operations. 
  

VDSL Point to Multipoint Solution  
(MEG801AE-R2 or MEG2401AE-R2 plus MEG101RAE-R2) 

 
MEG101RAE-R2 works together with the VDSL Quadband Switches 
MEG801AE-R2 and MEG2401AE-R2. Using these makes this system an ideal 
solution for delivering cost-effective, high-performance broadband/multimedia 
services to Multi-Dwelling Units (MDU) and Multi-Tenant Units (MTU) 
environments such as hotels, campus, hospitals and telecom. 
 

Interoperability MEG101AE and MEG101AE-R2 

 
Due to the completely different technology R2 and non R2 systems of this series 
are 

NOT COMPATIBLE

. You can not link any component of the older non-

Quadband series (like MEG801AE or MEG101AE) together with one of these top 
technology series (like MEG801AE-R2 or MEG101AE-R2). 

Summary of Contents for MEG101AE-R2

Page 1: ... eu _____________________________________________________________________________________________ ______________________________________________________________________________ Manual MEG101AE R2 Quadband VDSL Extender Kit MEG101RAE R2 Quadband VDSL Receiver ...

Page 2: ...operations is automatically sensed and configured VDSL link rates are configured by local Modem automatically MEG101AE R2 supports auto speed and plug play operations VDSL Point to Multipoint Solution MEG801AE R2 or MEG2401AE R2 plus MEG101RAE R2 MEG101RAE R2 works together with the VDSL Quadband Switches MEG801AE R2 and MEG2401AE R2 Using these makes this system an ideal solution for delivering c...

Page 3: ...e you can provide the right operating environment including power requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements The standard power supply coming with MEG101AE R2 and MEG101RAE R2 is intended for use in Central Europe only 220V It supplies 5V 1A For use in USA Japan Australia and UK please use Bl...

Page 4: ...o not recommend using 28 Gauge or above phone line The active pins are the two middle pins 3 and 4 To have a clear setup we recommend to have the VDSL line 1 1 straight through So for your notice only this VDSL device works crossed and straight through VDSL Port RJ 11 Pin out Pin FUNCTION 1 NC 2 NC 3 TIP 4 RING 5 NC 6 NC Phone Port RJ 11 Here you can connect FXS FXO equipment This means that on th...

Page 5: ...through your telephony wall socket outlet For making connectings you can alternatively use Patchpanels or anything else like terminal strips You just need to be sure that you have a good electrical connection So keep in mind that using stranded wires for use in Krone strips is not ideal Please note that connections are only operable between Transmitter and Receiver or between the switch MEG801AE R...

Page 6: ... 25 VDSL LED It will show you that a connection to the corresponding VDSL device has been successfully established The corresponding LED 5 15 or 25 will tell you what the transfer speed is This depends on the length and the quality of the wire Rear Panel Line For connecting to the the the other side Phone For connecting FXS FXO equipment Ethernet For connecting to your Ethernet device FG For groun...

Page 7: ...ice Check LED activity on your switch or corresponding Ethernet Device Verify that the proper cable type is used and its length does not exceed specified limits 100 Meter Check the Modem on the attached device and cable connections for possible defects Replace the defective Modem or cable if necessary Symptom VDSL Link cannot be established Cause VDSL auto speed failure or phone cable length is ov...

Page 8: ...used frequencies 900 KHz 3 9MHz and 4MHz 7 9MHz Supports 1 RJ 11 connector for Ethernet over VDSL Supports 1 RJ 11 connector for telephone PBX connection Supports 1 RJ 45 port for 10 100Mbps Ethernet with Auto MDI MDIX Supports Auto speed and full duplex for VDSL port Supports long packet size up to 1536 bytes Voice and Data work on the same 2 wire telephone line Supports flow control IEEE802 3x f...