13
CHAPTER 2: Introduction
2.1.5 R
ECEIVER
The receiver contains several circuits (shown in Figure 2-1 below):
• The RECEIVE FILTER removes all the out-of-band frequencies.
• The AUTOMATIC EQUALIZER is made up of several equalizers activated
according to data rate.
• The digital AGC (automatic gain control) automatically compensates for
the attenuation of the line. You can choose between the two modes of AGC
operations by setting the AGC jumper:
ON: The AGC operates continuously.
CNTR: The AGC is active only when DCD is ON. When DCD is OFF,
the AGC will remain in the state to which it was most recently set.
In full-duplex point-to-point applications, there is no difference between the
two AGC modes of operation.
Figure 2-1. Block diagram for the LDM-MR19.2.
Summary of Contents for ME760A-R2
Page 26: ...25 CHAPTER 3 Standalone Installation Figure 3 2 The standalone LDM MR19 2 s board layout...
Page 35: ...34 LDM MR19 2 Figure 4 3 The LDM MR19 2 card s board layout...
Page 38: ...37 CHAPTER 5 Operation Figure 5 2 The LDM MR19 2 card s front panel 1 2 3 4 5 7 A 6 B C D...
Page 46: ...NOTES...
Page 47: ...NOTES...