20
SYNC SHM-NPR MP
2. Strip the outer insulation from the twisted pairs
about one inch from the end.
Figure 4-4. Stripping the Outer Insulation from the Twisted Pairs.
3. Strip back the insulation on each of the two
twisted-pair wires about 0.25".
Figure 4-5. Stripping the Insulation on Each of the Two Twisted-Pair
Wires.
4. Connect one pair of wires to the two XMT
(transmit) poles on the terminal block. The Sync
SHM-NPR is not polarity sensitive, so either wire
may connect to either pole.
5. Connect the other pair of wires to the two RCV
(receive) poles on the terminal block. The Sync
SHM-NPR is not polarity sensitive, so either wire
may connect to either pole.