Chapter 3: Installation
3.2 Hardware Installation
3.2.1 Wiring the DC Power Inputs
Before installing the power input, make sure the DC power supply complies with standard power supply certifications.
NOTE: Suitable wire gauge is from 12 to 24 AWG.
Follow these steps to wire the DC power cable to the connector:
1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block connector.
2. Tighten the wire clamp screws to prevent the DC wires from loosening.
Wire clamp screws
V- and V+ contacts
Figure 3-2. Terminal block connector.
3.2.2 Wiring the Alarm Relay
The switch provides one dry relay output for a power or port link event. The alarm relay default is “open” and forms a closed
circuit when the event occurs. The relay conductor has a maximum of 24 Watts. When it connects with a 24-VDC power source,
the maximum current is 1 Amp. The following diagram shows how to create an alarm circuit.
WARNING: Do not connect to AC line.
Grounding screw
Ground
Figure 3-3. Alarm relay wiring.