DC Power Supply Wiring Instructions

The following diagram shows wiring configurations for 48 VDC power

supplies:

Specifications

AC Chassis

Environmental:

Operating Temperature:  32° - 122° F (0° - 50° C)
Storage Temperature:  20° - 160° F (-20° - 70° C)
Humidity:  5 - 95% (non-condensing)

Electrical:

AC Input Load: 100-240 VAC ±10%, 50/60 Hz, 1A max.

Dimensions:

1 Slot: 

1.55”H x 4.75”L x 7.31”D (3.94cm H x 12.07cm L x 18.57cm D)

Heat Generation:

51 BTU/hr. maximum

Forcing  the  Duplex  Mode

The LAN Extenders’ Ethernet port can be manually configured for either

Half- or Full-Duplex operation. Before manually setting the duplex mode,
disable Auto-Negotiation (Set Dip Switch 1 to 

OFF

.)

•  Configure the Ethernet port for Full-Duplex by setting Dip Switch 6 

to the 

ON

position (Default). 

•  Configure the Ethernet port for Half-Duplex by setting Dip Switch 6 

to the 

OFF

position.

Forcing  the  Speed  

The LAN Extenders’ Ethernet port can be manually configured for 10 or

100 Mbps operation.  Before manually setting the speed, disable Auto-
Negotiation (Set Dip Switch 1 to the 

OFF

position.)

•   Configure the Ethernet port for 10 Mbps operation by setting 

Dip Switch 5 to the 

OFF

position.

•   Configure the Ethernet port for 100 Mbps operation by setting 

Dip Switch 5 to the 

ON

position.

Flow  Control

Flow Control is used to throttle the END device to avoid dropping pack-

ets during network congestion.  Full-Duplex Flow Control will Advertise
ONLY in Full-Duplex Mode.  Full-Duplex Flow Control functions ONLY if
the link partner (end device) also has Flow Control.  Half-Duplex Flow
Control DOES NOT Advertise.  Configure the Ethernet port on the LAN
Extenders for Flow Control by setting Dip Switch 3 to the 

ON

position.

Link Fault  Propagate

Link Fault Propagate (LFP) is a troubleshooting feature.  When LFP is

enabled and the Host CO unit detects that the Remote CPE does not have
a copper link, LFP will disable the Host’s copper transmitter. Configure CO
LAN Extenders for LFP by setting Dip Switch 9 to the 

ON

position. Do not

enable LFP on CPE LAN Extenders. 

N O T E

The chasis is protected against mis-wiring. If mis-wired,

the chassis will not function.

Summary of Contents for LMC5220A

Page 1: ...y errors that may appear in this document Products are a trademark of Black Box Other brands or product names may be trademarks and are the property of their respective companies Document Number 50 80102BB 00 A0 February 2006 VDSL LAN Extender Products LMC5220A Standalone Set AC LMC5221A Standalone AC CO Unit LMC5222A Standalone AC CPE Unit LMC5223A Standalone Set Multi Power LMC5224A Standalone M...

Page 2: ...Notes 12 Notes ...

Page 3: ...hat any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indi cates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Followin...

Page 4: ...with an RJ 11 connector One 10 100 twisted pair Ethernet port with an RJ 45 con nector N O T E The LED functions are the same on both the CO and CPE modules Warranty Contact Black Box for warranty information Federal Communication Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 o...

Page 5: ...nnected to a 48V DC SELV source B Input wiring to terminal block must be routed and secured in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts C A readily accessible disconnect device with a 3mm minimum con tact gap shall be incorporated in the fixed wiring 3 Grounding reliable earthing of this equipment must be maintained Particular a...

Page 6: ...isted Pair Ethernet Port The twisted pair Ethernet port on the LAN Extenders hereon referred to as the Ethernet port auto negotiates for speed and duplex mode These also provide the option of manually setting the speed and duplex mode if the connected devices do not have the ability to auto negotiate or when Auto Negotiation is not preferred Auto N Negotiation The LAN Extenders ship from Black Box...

Page 7: ...re manually setting the speed disable Auto Negotiation Set Dip Switch 1 to the OFF position Configure the Ethernet port for 10 Mbps operation by setting Dip Switch 5 to the OFF position Configure the Ethernet port for 100 Mbps operation by setting Dip Switch 5 to the ON position Flow Control Flow Control is used to throttle the END device to avoid dropping pack ets during network congestion Full D...

Page 8: ...d 7 5 Mbps for Downstream Otherwise speed can be distributed in any combination between the Upstream and Downstream rates making data rates Asynchronous 12 5 Mbps and 2 1 5 Mbps and 10 Mbps etc The following chart provides examples of Synchronous and Asynchronous data rates at various distances 25 Mbps MAX Speed 6 5 Mbps 500 m 10 Mbps 2 Km MAX Distance 1 5 Km 15 Mbps 20 Mbps 1 Km 1 75 Km Distance ...

Reviews: