background image

3

8

Multi-Power Chassis 

DC Input Voltage: 

±7 to ±50 VDC on DC terminal 
5 to 20 VDC on DC jack

AC Wall Adapter:

100/240 ±10% VAC input, 5V DC output, 1A max.

Operating Temperature: 

-40° to +158°F (-40° to +70°C) excluding AC wall adapter; 
with AC wall adapter 32° to 122°F (0° to 50°C) 
NOTE: The stated temperature (-40° to +70°C) for the Multi-Power
chassis is only applicable when used with modules that also accommo-
date the same operating temperature.

Storage Temperature:

-49° to 185°F (-45° to +85°C)

Humidity: 

5 – 90% (non-condensing); 0 – 10,000 ft. altitude

Dimensions:

0.90”H x 4.30” L x 4.00”D (2.29cm H x 10.92cm L x 10.16cm D)

Black Box Customer Service

Order toll-free in the U.S.:

Call 877-877-BBOX 

(outside U.S. call 724-746-5500)
FREE technical support, 24 hours a day, 7 days a week

Call: 

724-746-5500 or 

Fax:

724-746-0746

Mail order:

Black Box Corporation 

1000 Park Drive, Lawrence, PA 15055-1018

Web site:

www.blackbox.com   

E-mail:

[email protected]

CO  as  Host  for  Remote  Management  of  CPE

Configuring the CO LAN Extender as a Host allows remote management

of the CPE LAN Extender. Configure the CO LAN Extender as a Host by set-
ting the Dip Switch 8 to the 

ON

position. The VDSL ports must be con-

nected and a link established prior to managing the remote unit.

The 10/100 Twisted Pair Ethernet Port

The twisted pair Ethernet port on the LAN Extenders (hereon referred to

as the Ethernet port) auto-negotiates for speed and duplex mode. These also
provide the option of manually setting the speed and duplex mode if the
connected devices do not have the ability to auto-negotiate, or when 

Auto-

Negotiation

is not preferred.

Auto-N

Negotiation

The LAN Extenders ship from Black Box with Auto-Negotiation enabled

on the Ethernet port. In this mode, the Ethernet port negotiates for speed
and duplex (i.e. the LAN Extender autosenses 10 Mbps Full-Duplex, 10
Mbps Half-Duplex, 100 Mbps Full-Duplex or 100 Mbps Half-Duplex with
Flow Control).  Configure Auto-Negotiation on the LAN Extenders by adjust-
ing the DIP switch.

Selective  Advertising

Selective Advertising, when used in combination with Auto-Negotiation,

advertises only the configured speed and duplex mode for the Ethernet port.
If Selective Advertising and Auto-Negotiation are both switched 

ON

,  the

Ethernet port’s speed (10 or 100 Mbps) and Duplex mode (FDX or HDX) can
be manually configured.  Configure the Ethernet port for Selective
Advertising by setting Dip Switches 4 and 5 to the 

ON

position, then select-

ing the speed and duplex.

N O T E

If a specific speed and/or duplex mode is required, use Selective Advertising rather
than Force Mode, when connecting to devices that ONLY auto-negotiate. Selective
Advertising is NOT an option when disabling Auto-Negotiation

Summary of Contents for LMC5220A

Page 1: ...y errors that may appear in this document Products are a trademark of Black Box Other brands or product names may be trademarks and are the property of their respective companies Document Number 50 80102BB 00 A0 February 2006 VDSL LAN Extender Products LMC5220A Standalone Set AC LMC5221A Standalone AC CO Unit LMC5222A Standalone AC CPE Unit LMC5223A Standalone Set Multi Power LMC5224A Standalone M...

Page 2: ...Notes 12 Notes ...

Page 3: ...hat any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indi cates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Followin...

Page 4: ...with an RJ 11 connector One 10 100 twisted pair Ethernet port with an RJ 45 con nector N O T E The LED functions are the same on both the CO and CPE modules Warranty Contact Black Box for warranty information Federal Communication Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 o...

Page 5: ...nnected to a 48V DC SELV source B Input wiring to terminal block must be routed and secured in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts C A readily accessible disconnect device with a 3mm minimum con tact gap shall be incorporated in the fixed wiring 3 Grounding reliable earthing of this equipment must be maintained Particular a...

Page 6: ...isted Pair Ethernet Port The twisted pair Ethernet port on the LAN Extenders hereon referred to as the Ethernet port auto negotiates for speed and duplex mode These also provide the option of manually setting the speed and duplex mode if the connected devices do not have the ability to auto negotiate or when Auto Negotiation is not preferred Auto N Negotiation The LAN Extenders ship from Black Box...

Page 7: ...re manually setting the speed disable Auto Negotiation Set Dip Switch 1 to the OFF position Configure the Ethernet port for 10 Mbps operation by setting Dip Switch 5 to the OFF position Configure the Ethernet port for 100 Mbps operation by setting Dip Switch 5 to the ON position Flow Control Flow Control is used to throttle the END device to avoid dropping pack ets during network congestion Full D...

Page 8: ...d 7 5 Mbps for Downstream Otherwise speed can be distributed in any combination between the Upstream and Downstream rates making data rates Asynchronous 12 5 Mbps and 2 1 5 Mbps and 10 Mbps etc The following chart provides examples of Synchronous and Asynchronous data rates at various distances 25 Mbps MAX Speed 6 5 Mbps 500 m 10 Mbps 2 Km MAX Distance 1 5 Km 15 Mbps 20 Mbps 1 Km 1 75 Km Distance ...