background image

USER MANUAL

24/7 TECHNICAL SUPPORT AT 1.877.877.2269 OR VISIT BLACKBOX.COM

LHC210A, LHC211A, LHC212A, LGC210A, LGC211A, LGC212A, LHGC-RACK

MEDIA 

CONVERTERS 

AND CHASSIS

Summary of Contents for LGC210A

Page 1: ...USER MANUAL 24 7 TECHNICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM LHC210A LHC211A LHC212A LGC210A LGC211A LGC212A LHGC RACK MEDIA CONVERTERS AND CHASSIS ...

Page 2: ... 2 Set the DIP Switches LHC210A LHC211A and LHC212A Only 13 3 2 Installing the Converter as a Standalone Unit 15 3 2 1 Connect the Media Cables LHC210A LHC211A LHC212A LGC210A LGC211A LGC212A 15 3 3 Installing the Media Converters in the 14 Slot Chassis 15 3 3 1 Install the Chassis in a 19 Cabinet or Rack 15 3 3 2 Plug the Media Converters into the Chassis Slots 15 3 3 3 Connect the Network Cables...

Page 3: ...0BASE TX 100BASE FX LGC210A LGC211A LGC212A 10 100BASE TX 1000BASE TX 1000BASE FX Media Supported 10 100 1000BASE T CAT5 UTP STP max 328 ft 100 m 100 1000BASE FX Connectors All 1 RJ 45 LHC210A LGC210A 1 SFP slot LHC211A LGC211A 1 MM SC LHC212A LGC212A 1 SM SC User Controls LHC210A LHC211A LHC212A 2 4 position DIP switches C210A Maximum Distance LHC210A LGC210A Depends on SFP installed LHC211A 1 2 ...

Page 4: ...SFP module slot Twisted pair port supports auto adaption rate and full half duplex mode as well as auto MDI MDI X Six LEDs indicate optical power and twisted pair port status Chassis includes a built in power supply and Media Converters come with an external power supply which will not be used if they are going to be used in the chassis Optional 2U chassis holds up to 14 media converters for conve...

Page 5: ...45 connector Links to RJ 45 cable 4 Barrel connector for power Links to 47 57 VDC power supply 5 2 4 position DIP switches numbered 1 8 See Table 3 2 TABLE 2 2 LHC210A LED INDICATORS LED NAME STATUS DESCRIPTION PWR ON Power is ON and normal FX Link ACT ON Connection Status display for fiber link ON indicates that the fiber link is correctly connected Blinking Packet is being transmitted through th...

Page 6: ...5 connector Links to RJ 45 cable 4 Barrel connector for power Links to 47 57 VDC power supply 5 2 4 position DIP switches numbered 1 8 See Table 3 2 TABLE 2 4 LHC211A LED INDICATORS LED NAME STATUS DESCRIPTION PWR ON Power is ON and normal FX Link ACT ON Connection Status display for fiber link ON indicates that the fiber link is correctly connected Blinking Packet is being transmitted through the...

Page 7: ...5 connector Links to RJ 45 cable 4 Barrel connector for power Links to 47 57 VDC power supply 5 2 4 position DIP switches numbered 1 8 See Table 3 2 TABLE 2 6 LHC212A LED INDICATORS LED NAME STATUS DESCRIPTION PWR ON Power is ON and normal FX Link ACT ON Connection Status display for fiber link ON indicates that the fiber link is correctly connected Blinking Packet is being transmitted through the...

Page 8: ...e 2 8 3 RJ 45 connector Links to RJ 45 cable 4 Barrel connector for power Links to 47 57 VDC power supply TABLE 2 8 LGC210A LED INDICATORS LED NAME STATUS DESCRIPTION PWR ON Power is ON and normal FX Link ACT ON Connection Status display for fiber link ON indicates that the fiber link is correctly connected Blinking Packet is being transmitted through the FX end SD ON Fiber signal is detected 1000...

Page 9: ...rs See Table 2 10 3 RJ 45 connector Links to RJ 45 cable 4 Barrel connector for power Links to 47 57 VDC power supply TABLE 2 10 LGC211A LED INDICATORS LED NAME STATUS DESCRIPTION PWR ON Power is ON and normal FX Link ACT ON Connection Status display for fiber link ON indicates that the fiber link is correctly connected Blinking Packet is being transmitted through the FX end SD ON Fiber signal is ...

Page 10: ...cators See Table 2 12 3 RJ 45 connector Links to RJ 45 cable 4 Barrel connector for power Links to 47 57 VDC power supply TABLE 2 12 LGC212A LED INDICATORS LED NAME STATUS DESCRIPTION PWR ON Power is ON and normal FX Link ACT ON Connection Status display for fiber link ON indicates that the fiber link is correctly connected Blinking Packet is being transmitted through the FX end SD ON Fiber signal...

Page 11: ...ws the back of the rackmount chassis Table 2 13 describes its components 1 2 3 FIGURE 2 13 LHGC RACK FRONT VIEW 4 5 4 5 FIGURE 2 14 LHGC RACK BACK VIEW TABLE 2 13 MEDIA CONVERTER CHASSIS COMPONENTS NUMBER IN FIGURE 2 12 OR 2 14 COMPONENT DESCRIPTION 1 Blank slot cover SFP module installs here 2 Media Converter Media Converter installs here 3 Rackmount ears Attaches to 19 rack or cabinet 4 3 prong ...

Page 12: ... LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 1 877 877 2269 BLACKBOX COM CHAPTER 2 OVERVIEW 2 5 APPLICATION DIAGRAM INTERNET MEDIA CONVERTER MEDIA CONVERTER FIBER MULTI WA BROADBAND ROUTER SWITCH COMPUTER FIGURE 2 15 APPLICATION DIAGRAM ...

Page 13: ...SFP 1250 Mbps Extended Diagnostics 850 nm Multimode Fiber 550 m LC LGC210A LFP412 SFP 1250 Mbps Extended Diagnostics 1310 nm Multimode Fiber 2 km LC LGC210A LFP413 SFP 1250 Mbps Extended Diagnostics 1310 nm Single Mode Fiber 10 km LC LGC210A LFP414 SFP 1250 Mbps Extended Diagnostics 1310 nm Single Mode Fiber 30 km LC LGC210A LFP418 SFP 1250 Mbps Extended Diagnostics 1550 nm Single Mode Fiber 80 km...

Page 14: ...d enabled OFF Force fiber port to full duplex mode OFF IEEE 802 3x enabled ON IEEE 802 3x disabled OFF OFF OFF Force TX port to 10M 100M full duplex half duplex with auto negotiation OFF OFF ON Force TX port to 10M 100M half duplex with auto negotiation OFF ON OFF Force TX port to 10M full duplex half duplex with auto negotiation OFF ON OFF Force TX port to 10M half duplex with auto negotiation ON...

Page 15: ...your power requirements 3 3 1 INSTALL THE CHASSIS IN A 19 CABINET OR RACK Install the media converter chassis in a standard 19 rack or cabinet and secure it with screws not included 3 3 2 PLUG THE MEDIA CONVERTERS INTO THE CHASSIS SLOTS 1 Unscrew the two screws next to the RJ 45 port of the first media converter Use these two screws to affix the media converter to the chassis 2 Insert the media co...

Page 16: ...ICAL SUPPORT 1 877 877 2269 1 877 877 2269 BLACKBOX COM CHAPTER 3 INSTALLING THE CONVERTER 3 4 INSTALLATION DIAGRAM FP RX PWR LINK ACT FDX COL 1000M TX SWITCH SWITCH STP STP TP MC RX TX FP PWR LINK ACT FDX COL 1000M TP FIGURE 3 2 TYPICAL INSTALLATION ...

Page 17: ...t with a new power supply and connect the plug When a single power supply broken down follow the above steps The converters installed in the chassis will stop working until a new power supply is installed and working normally 4 2 TROUBLESHOOTING TABLE 4 1 PROBLEMS CAUSES SOLUTIONS PROBLEM CAUSE POSSIBLE SOLUTION Poewr LEDs are OFF Power plug not connected or not a valid connection Connect the powe...

Page 18: ...on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult an experienced radio TV technician for help CAUTION Changes or modifications not expressly ...

Page 19: ...tes que impidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el apar...

Page 20: ...ve consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice B 2 TRADEMARKS USED IN THIS MANUAL Black Box and the Black Box logo type and mark are registered trademarks of Black Box Corporation Any other trademarks mentioned in this manual are...

Page 21: ..._______ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 22: ..._______ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 23: ..._______ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 24: ...NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 COPYRIGHT 2018 BLACK BOX CORPORATION ALL RIGHTS RESERVED LHC210A_USER_REV1 PDF ...

Reviews: