background image

LE2127A-R3 IN THE NETWORK

NOTE: AUI drop cable also can be used to connect to the transceiver.  

Using LinkAlert™

The LinkAlert™ feature allows the transceiver to pass 10BASE-FL-side link faults
to the AUI side and to pass AUI-side link faults to the 10BASE-FL side.

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3

Case Dimensions

              3.8" x 1.65" x 0.94 inches  (95 mm x 42 mm x 24 mm)

 

Weight

3.5 oz. (99.2 g)

Environment

Temperature:

0-40°C (32° to 104° F )

Humidity

10-90%, non condensing 

Altitude

0-10,000 feet

Power

11.4 - 16.5 VDC, 
175 mA (typical), 300 mA (maximum)

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Black Box Corporation
1000 Park Drive, Lawrence PA 15055 USA

Model:

AUI/10BASE-FL Transceiver

Part Number:

LE2127A-R3, LE2127A-SC-R3, LE2127A-SM-R3

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the LE2127A-R3 to which this declaration refers is in

conformity with the following standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_January 11, 2000_____

Stephen Anderson, Vice-President of Engineering

Date

10BASE-FL Hub

OR

OR

Hub with AUI connector

SQE = ON

S

TAT

U

S

RX

TX

COL

ON = OK

ST

A

TUS

RX

TX

COL

ON = OK

S

TAT

U

S

RX

TX

COL

ON = OK

SQE = OFF

SQE = ON

10BASE-FL

Device

Transceiver

FAULT INDICATION*

LINK FAULT INDICATION

Network

Device

AUI

Summary of Contents for LE2127A-R3

Page 1: ...hines aimed at preventing radio interference in commercial and or industrial areas When used in a residential area or in an adjacent area thereto interference may be caused to radio and TV receivers etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 Black Box Corporation Al...

Page 2: ...on 1000 Park Drive Lawrence PA 15055 USA Model AUI 10BASE FL Transceiver Part Number LE2127A R3 LE2127A SC R3 LE2127A SM R3 Regulation EMC Directive 89 336 EEC Purpose To declare that the LE2127A R3 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 IEC 801 3 and IEC 801 4 IEC 950...

Page 3: ...Mode UP Enable half duplex mode when connecting to half duplex network devices DOWN Enable full duplex mode when connecting to full duplex network devices Default is enabled UP NOTE DO NOT USE FULL DUPLEX WHEN CONNECTING THE TRANSCEIVER TO A REPEATER 4 Not Used Install Cable NOTE See page 6 for cable specifications and configurations FIBER Locate or build 10BASE FL compliant fiber cable with male ...

Page 4: ...minated amber LED indicates packet transmission AUI to fiber RX Flashing or illuminated amber LED indicates packet reception fiber to AUI FAULT ISOLATION and CORRECTION If the transceiver fails determine the answers to the following questions 1 Is the STATUS LED on the transceiver illuminated NO Verify that the transceiver is installed properly in the AUI port and that the DTE device is powered ON...

Reviews: