background image

CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications. 

Fiber Cable 

Multimode Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Singlemode Cable Recommended:

9/125 µm singlemode fiber

Bit

error rate:

10

-9

LE2127A-R3

850nm multimode - with ST connectors

Fiber-optic Transmitter Power:

min: -16.0 dBm

max: -10.0 dBm

Fiber-optic Receiver Sensitivity:

min:  -29.5 dBm

max: -7.2 dBm

Typical Maximum Cable Distance*:

2 kilometers (6,600 feet)

LE2127A-R3(SC) 

850nm multimode - with SC connector

Fiber-optic Transmitter Power:

min: -16.0 dBm

max: -10.0 dBm

Fiber-optic Receiver Sensitivity:

min:  -29.5 dBm

max: -7.2 dBm

Typical Maximum Cable Distance*:

2 kilometers (6,600 feet)

LE2127A-R3(SM) 

1300nm singlemode - with ST connectors

Fiber-optic Transmitter Power:

min: -27.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

20 kilometers (66,000 feet)

*Actual distance dependent upon physical characteristics of network installation.

AUI (DB-15) Interface 

INSTALLATION 

Set Switches

NOTE: UP enables the indicated function on
the 4-position switch located to the right of the
10BASE-FL connector and DOWN disables the
indicated function.

1

SQE Test:  (UP) Enable SQE test
function when connecting to other devices.  (DOWN) Disable SQE
test function when connecting to IEEE 802.3 compliant repeaters.
Default is enabled (UP).

2

LinkALERT(UP) Enable the LinkALERT

function.  (DOWN)

Enable standard Link Integrity Test. Default is enabled (UP).

3

Half-Duplex/Full-Duplex Mode:  (UP) Enable half-duplex mode
when connecting to half-duplex network devices.  (DOWN) Enable
full-duplex mode when connecting to full-duplex network devices.
Default is enabled (UP) NOTE: DO NOT USE FULL-DUPLEX
WHEN CONNECTING THE 

TRANSCEIVER

TO A REPEATER. 

4

Not Used

Install Cable

NOTE: See page 6 for cable specifications and configurations. 

FIBER

Locate or build 10BASE-FL compliant fiber cable with male two-
stranded TX to RX connectors at both ends.

Connect male TX and RX cable connectors at one end of cable to
TX and RX female connectors, respectively, on media converter.

Connect female TX and RX cable connectors at other end of
cable to RX and TX connectors of 802.3 compliant fiber device.

AUI

DROP CABLE

Connect AUI drop cable female connector to male AUI (DTE)
connector on LE2127A-R3.

Connect other end of AUI drop cable to 10BASE-5 network.

NETWORK DEVICE

Connect device female connector to male AUI (DTE) connector
on LE2127A-R3.

Connect to Power

The LE2127A-R3 is powered through the AUI connection.

Parameter

Minimum

Typical

Maximum

Transmit
Transmit threshold voltage level:

-140mV

-170mV

-190mV

Transmit turn on delay:

100ns

Transmit steady propagation delay:

15ns

50ns

Transmit loop back start up delay:

500ns

Transmit turn off to data idle:

400ns

2100ns

SQE test delay:

0.6 µ sec

1.6 µ sec

SQE test duration:

0.5 µ sec

1.0 µ sec

1.5 µ sec

Receive
Receive turn on delay:

350ns

Receive steady propagation delay:

15ns

50ns

Differential output voltage (RX(-/+)):

(+/-)550mV

(+/-)1200

Differential output voltage (col(-/+)):

(+/-)550mV

(+-)1200

Differential output rise time (RX(-/+), col(-/+)): 4ns
Differential output fall time (RX(-/+), col(-/+)): 4ns
Collision
Time for SQE to deact. after collision:

450ns

700ns

Collision frequency:

8.5MHz

11.5MHz

Collision pulse duty cycle:

40%

50%

60%

SQE test delay:

0.6 µ sec

1.6 µ sec

Jabber activation delay:

20ms

70ms

150ms

1       2      3     4 

Summary of Contents for LE2127A-R3

Page 1: ...hines aimed at preventing radio interference in commercial and or industrial areas When used in a residential area or in an adjacent area thereto interference may be caused to radio and TV receivers etc Read the instructions for correct handling Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2000 Black Box Corporation Al...

Page 2: ...on 1000 Park Drive Lawrence PA 15055 USA Model AUI 10BASE FL Transceiver Part Number LE2127A R3 LE2127A SC R3 LE2127A SM R3 Regulation EMC Directive 89 336 EEC Purpose To declare that the LE2127A R3 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 IEC 801 3 and IEC 801 4 IEC 950...

Page 3: ...Mode UP Enable half duplex mode when connecting to half duplex network devices DOWN Enable full duplex mode when connecting to full duplex network devices Default is enabled UP NOTE DO NOT USE FULL DUPLEX WHEN CONNECTING THE TRANSCEIVER TO A REPEATER 4 Not Used Install Cable NOTE See page 6 for cable specifications and configurations FIBER Locate or build 10BASE FL compliant fiber cable with male ...

Page 4: ...minated amber LED indicates packet transmission AUI to fiber RX Flashing or illuminated amber LED indicates packet reception fiber to AUI FAULT ISOLATION and CORRECTION If the transceiver fails determine the answers to the following questions 1 Is the STATUS LED on the transceiver illuminated NO Verify that the transceiver is installed properly in the AUI port and that the DTE device is powered ON...