16
ASYNC RS-232 TO 2-WIRE RS-485 CONVERTER
5. Connect the same pair of wires to XMT A and
XMT B on the RS-485 device, respectively, as
shown in
Table 4-2
.
Table 4-2. Crossover Cable Connection.
Converter
RS-485 Device
XMT+ - - - - - - - - - - - - - - - XMT A
XMT- - - - - - - - - - - - - - - - - XMT B
6. Place the two halves of the strain-relief assembly
on either side of the telephone wire and press
together very lightly. Slide the assembly so that it is
about 2 inches (5 cm) from the terminal posts and
press together firmly.
7. Insert the strain-relief assembly with the wire going
through it into the slot in the bottom half of the
Converter case and set it into the recess in the
case.