Page 1: ...24 7 TECHNICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM 48 PORT 1G IP NETWORK SWITCH HARDWARE INSTALLATION GUIDE EMS1G 48...

Page 2: ...1 3 1 Site Selection 11 3 2 Cabinet Placement 11 3 3 Rackmounting 11 3 4 Switch Ground 11 3 5 Fans and Airflow 12 3 6 Power 12 3 7 Storing Components 12 4 NEBS COMPLIANCE 13 5 INSTALLING THE SWITCH 14...

Page 3: ...3 ONiE Service Discovery 31 9 TROUBLESHOOTING 33 9 1 Contacting Technical Support 33 9 2 Shipping and Packaging 33 APPENDIX A REGULATORY INFORMATION 34 A 1 USA Federal Communications Commission Statem...

Page 4: ...handling this equipment WARNING Only trained and qualified personnel can install this equipment Read this guide before you install and power up this equipment This equipment contains two power cords...

Page 5: ...eues Layer 2 VLANs 4K MSTP 64 instances VRF lite 64 instances Line rate Layer 2 switching all protocols including IPv4 and IPv6 Line rate Layer 3 routing IPv4 and IPv6 IPv4 host table size up to 40k m...

Page 6: ...with 2GB DDR III RAM Temperature monitoring Software readable thermal monitor Real time clock RTC support Hot plug redundant power supply Power management monitoring Removable fans Standard 1U chassis...

Page 7: ...N FIGURE 2 1 COMPONENT DESCRIPTION 1 48 RJ 45 ports Links to 10 100 1000BASE T devices 2 4 SFP ports SFP modules install here 3 1 RJ 45 port Links to serial console 4 1 USB 2 0 port Console Port becom...

Page 8: ...2 OVERVIEW 2 5 2 BACK PANEL Figure 2 2 shows the back panel of the switch Table 2 3 describes its components FIGURE 2 2 BACK PANEL OF THE SWITCH TABLE 2 3 BACK PANEL COMPONENTS NUMBER IN FIGURE 2 2 C...

Page 9: ...their functions FIGURE 2 3 LEDS ON THE SWITCH TABLE 2 4 LEDS ON THE SWITCH NUMBER IN FIGURE 2 3 NAME OF LED DESCRIPTION 1 System Status Health LED Solid green Normal operation Blinking green Booting S...

Page 10: ...US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 CHAPTER 2 OVERVIEW TABLE 2 4 LEDS ON THE SWITCH NUMBER IN FIGURE 2 3 NAME OF LED DESCRIPTION 6 Management Ethernet Port Link LED Off No Link Solid green L...

Page 11: ...o 95 F 10 to 35 F Operating humidity is from 5 to 85 percent noncondensing Storage humidity is from 5 to 95 percent noncondensing In a dry clean well ventilated and temperature controlled room away fr...

Page 12: ...th the switch When installing AC switches follow the requirements of the National Electrical Code ANSI NFPA 70 where applicable The switch is powered up as soon as the power cord is connected between...

Page 13: ...to a commercial AC power source you must connect the switch to an external special protection device SPD To be NEBs compliant you must follow these regulations Locate your switch in a restricted acces...

Page 14: ...OTE Do not the use the mounted rails as a shelf or a workplace 5 2 1 RACKMOUNT SAFETY CONSIDERATIONS Rack loading Overloading or uneven loading of racks may result in shelf or rack failure causing dam...

Page 15: ...post threaded 1 With the rail flange ears facing outward place one rail between the left and right vertical posts Align and seat the rear flange rail pegs in the rear vertical post flange In the foll...

Page 16: ...from each front flange ear on the switch side of the rail and remove each casting Retain the castings for future rack requirements It is not necessary to remove the rear flange castings 2 3 1 FIGURE...

Page 17: ...ALLATION 1 Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user supplied screws item 1 1 2 FIGURE 5 3 TWO POST CENTER MOUNT CONFI...

Page 18: ...iguration remove the flange ear castings from each end of the rail assemblies To remove the two screws from each flange ear and remove each casting use a Torx driver item 1 Retain the castings for fut...

Page 19: ...anner as the four post configurations 1U FRONT RACK INSTALLATION Configure the rails that are attached to the switch 1 Attach the inner chassis members switch rails to the EMS1G 48 switch Item 3 shows...

Page 20: ...opper Do not use aluminum conductors NOTE The rack installation ears are not suitable for grounding NOTE Coat the one hole lug with an antioxidant compound before crimping Also bring any unplated mati...

Page 21: ...6 OPTICS REMOVAL Remove an optic by pushing the tab on the optic and sliding the optic from the port When removing optics with direct attach cables DACs from the port pull the release tab firmly and...

Page 22: ...P LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 CHAPTER 5 INSTALLING THE SWITCH Power up sequence When the switch powers up the fans immediately come on at high speed The fan speed s...

Page 23: ...ck Box recommends using power supply 2 PSU2 as the blank plate slot Use a 1 Philips screw driver to install the blank plate NOTE ESD damage can occur if components are mishandled Always wear an ESD pr...

Page 24: ...e first slot PSU1 and installing a blank plate in the second slot PSU2 1 Remove the PSU slot cover from the switch using a small 1 Phillips screwdriver 2 Remove the PSU from the electro static bag 3 I...

Page 25: ...omponents in the PSU To request a hardware replacement contact Black Box Technical Support at 877 877 2269 or info blackbox com NOTE If you use a single PSU install a blank plate in the other PSU slot...

Page 26: ...PSUs in a configuration must be in the same airflow direction Environmental factors can decrease the amount of time required between fan replacements Check the environmental factors regularly An incr...

Page 27: ...LACEMENT CAUTION Complete steps 1 and 2 within one minute or the switch powers down 1 Slide the fan module out of the bay 2 Slide the replacement module into the bay 7 4 AFTER INSTALLING THE SWITCH Af...

Page 28: ...cannot accept a female DB9 connector acquire a DB9 male to male adapter 1 Install the provided RJ 45 connector side of the provided cable into the switch console port 2 Install the DB9 female side of...

Page 29: ...nstall the necessary USB device drivers To download the drivers contact Black Box Technical Support at 877 877 2269 or info blackbox com 6 Open your terminal software emulation program to access the s...

Page 30: ...ailed No such device or address 4 OPTIONAL Add a device to the file systems table fstab and mount the file systems ONIE vi etc fstab FSTAB entry for the ONIE BOOT partition mounted on boot LABEL ONIE...

Page 31: ...For downloading and updating ONIE from a URL ONIE Embed ONIE For downloading and updating ONIE from a URL and erases any installed O ONIE Diag ONIE Run Diagnostic package for EMS1G 48 Run Black Box N...

Page 32: ...255 255 0 To display the IP address use the ifconfig eth0 command as shown ONIE ifconfig eth0 eth0 Link encap Ethernet HWaddr 90 B1 1C F4 9C 76 inet addr 10 11 53 33 Bcast 10 255 255 255 Mask 255 0 0...

Page 33: ...e will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in...

Page 34: ...ation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures necessary to correct the interference at their own...

Page 35: ...tes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros apar...

Page 36: ...the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial and industrial environments to pr...

Page 37: ...1st Edition EN 60825 1 Safety of Laser Products Part 1 Equipment Classification Requirements and User s Guide EN 60825 2 Safety of Laser Products Part 2 Safety of Optical Fibre Communication Systems...

Page 38: ...system according to applicable local and national regulations Black Box encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed Wast...

Page 39: ...e consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any tim...

Page 40: ...NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 COPYRIGHT 2018 BLACK BOX CORPORATION ALL RIGHTS RESERVED EMS1G 48_INSTALL_REV1 PDF...