CHAPTER 8: RS-232 CONTROL
1.877.877.2269
BLACKBOX.COM
TABLE 8-7. EDID MANAGEMENT CONTINUED
COMMAND
FUNCTION
FEEDBACK EXAMPLE
EDIDSTA[XX].
Query EDID status of Input port
[xx]=00 to 08
(xx=01 to 08 is the number of input port. If xx=00, it means all input ports.)
NOTE:
If built-in EDID09 is not user-defined, when querying it, the input port will use
EDID6 Internal EDID instead. For example, send “EDID/03/09.”, “EDIDSTA03.”
produces “Input 03 EDID From 06 Internal EDID!”.
If built-in EDID09 has been user-defined, when querying it, the input port will
use the user-defined EDID. For example, send “EDID/03/09.”, “EDIDSTA03.”
produces “Input 03 EDID From User Define EDID!”.
If you directly user-define the port EDID, when querying it, the input port will use
the user-defined EDID. For example, send “EDIDSTA03.” produces “Input 3 EDID
From User Define EDID!”
Input 01 EDID From
01 Internal EDID!
Input 02 EDID From
02 Internal EDID!
Input 03 EDID From
03 Internal EDID!
Input 04 EDID From
06 Internal EDID!
Input 05 EDID From
06 Internal EDID!
Input 06 EDID From
06 Internal EDID!
Input 07 EDID From
06 Internal EDID!
Input 08 EDID From
User Define EDID!