DVI-D CAT X KVM-EXTENDER
28
Loading the DDC Information from the Remote Monitor into the
internal DDC Table
To load the DDC Information from the Remote Monitor into the internal DDC Table,
please proceed the following steps:
•
Switch off the Local Unit and the Remote Unit, unplug the Video-Cable to the Remote
Monitor (Dualhead devices: BOTH Monitors!)
•
Open the Local Unit like described above
•
Unplug Jumper JP3 and plug it to Position JP2 (Please bear in mind the position of JP3.
Note: both – JP1 and JP2 are plugged now - Dualhead devices: jumper setting on BOTH
PCB’s!)
•
Switch on the Local and Remote Unit (Please ensure, the interconnect cable – CATx or
fiber is connected - Dualhead devices: BOTH interconnect cables!)
•
Wait until the LINK-LED is illuminated (see above)
•
Plug the Video-Cable of the Remote Monitor into the remote unit (switch on the Monitor
if swiched off - Dualhead devices: BOTH Monitors!))
•
The DDC Information of the Remote Monitors is read automatically, transfered to the
Local Unit and stored into the DDC-EPROM
•
After a successful programming of the DDC EPROM, the ‚Video-OK’ LED at the
Local Unit is blinking rapidly for approx. 1 second
•
Switch off the Local Unit and the Remote Unit
•
Unplug Jumper JP2 and plug it back to Position JP3 as kept in mind (Dualhead devices:
jumper setting on BOTH PCB’s!)
•
Close the Local Unit like described above
•
Switch on the Local Unit and the Remote Unit
•
Done