4

checked periodically to confirm its functionality and for loss of reception; also check for loss of reception after moving
the unit to a different location.
• Test Warnings from NOAA; all National Weather Services periodically transmit test signals. Some stations broadcast a
test signal every week on Wednesday between 11 AM and 1 PM, while others test more often, the NWS may also
broadcast System demonstrations. You can find out when your local NWS broadcasts test signals by calling the NOAA
National Weather Service Forecast Office (listed under “Weather” in the Federal Government section of the telephone
book.) During the weekly test signal, the local NWS will give a list of counties covered by their transmitter.
• Check unit periodically for wear and tear. Take to a qualified technician for replacement of worn or defective parts
immediately.
• Read This Instruction Manual Before Using This Unit.

SAVE THESE INSTRUCTIONS

INTRODUCTION

Thank you for purchasing the 

PS50LRB Rechargeable Portable Power Station/Radio/Lantern.

Please

read this guide carefully before use to ensure optimum performance and to avoid damage to the unit. 

FEATURES

• Powerful fluorescent lantern
• Ultra bright 6-LED Backup Light
• Built-in 50 watt inverter
• Portable 12 volt DC power for charging mobile phones and other personal devices
• AM, FM and Weather Band radio with automatic NOAA Weather/Emergency Alert System
• Telescoping antenna
• Rechargeable, internal backup Ni-MH battery
• Hand-Crank Dynamo and 120 Volt AC Adapter (included) to recharge backup batteries
• Battery Charge Level and Charging Indicators
• Collapsible Handle/Hanging Hook
• Protective cage

Protective Features

• 

Automatic Overload —

Built-in protection against overload — in the event the AC outlet draws more than 50 watts,

power to the unit’s outlet will automatically shut off.

• 

Ground Fault Circuit Interrupter (GFCI) —

The GFCI protects the unit and the user by sensing imbalances in a circuit

caused by current leakage to the ground and shuts down the unit’s AC outlet to prevent electrical shock.

• 

Overheating —

Unit automatically shuts down if it exceeds a safe temperature.

• 

Low Battery —

If the battery power level is too low, the AC Power Supply shuts down automatically.

This device complies with part 15 of the FCC rules. Operation is subject to the following two

conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device,

pursuant to part 15 of the FCC Rules, These limits are designed to provide reasonable protection
against harmful interference to radio communications. However, there is not guarantee that
interference to radio or television reception, with can be determined by turning the equipment off and
on, user is encouraged to try to connect the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between equipment and receiver.
• Connect equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

PS50LRB_Manual_120106  12/1/06  11:25 AM  Page 4

Summary of Contents for PS50LRB

Page 1: ... 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER TO REDUCE THE RISK OF INJURY THE USER MUST READ AND UNDERSTAND THE INSTRUCTION MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Cat PS50LRB Form 90510946 SEP...

Page 2: ...ng and balance at all times DISCONNECT APPLIANCES Disconnect the appliance from the power supply when not in use before servicing and when changing accessories such as blades and the like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in GROUND FAULT CIRCUIT INTERRUPTER GFCI protection should be provided on the circuits or ou...

Page 3: ...for which it was designed Read and understand all warnings and operating instructions before using any tool or equipment SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE POWER STATION RADIO LANTERN MODEL PS50LRB IMPORTANT SAFETY INSTRUCTIONS WARNING This product or its power cord contains lead a chemical known to the State of California to cause canc...

Page 4: ...which can be attributed to any of the following a Improper antenna setup To ensure you get the best available reception extend the built in antenna and adjust its direction to provide maximum reception b Improper tuner setup To ensure you are always tuned in to receive the NOAA alerts check the National Weather Service website http www nws noaa gov nwr nwrbro htm for the signal frequency in your a...

Page 5: ...harge backup batteries Battery Charge Level and Charging Indicators Collapsible Handle Hanging Hook Protective cage Protective Features Automatic Overload Built in protection against overload in the event the AC outlet draws more than 50 watts power to the unit s outlet will automatically shut off Ground Fault Circuit Interrupter GFCI The GFCI protects the unit and the user by sensing imbalances i...

Page 6: ...ND CRANK LED INDICATOR 12 VOLT DETACHABLE BATTERY PACK COLLAPSABLE HANDLE HANGING HOOK DYNAMO HAND CRANK WHEN COLLAPSED SEE BELOW DYNAMO HAND CRANK ALERT LED INDICATOR RADIO TUNER KNOB RADIO BAND STATION DISPLAY ALARM LOCK LED INDICATOR RADIO POWER LED INDICATOR ALERT ON OFF PUSHBUTTON RADIO BAND SELECTOR OFF AM FM WX VOLUME CONTROL KNOB ALARM LOCK ON OFF PUSHBUTTON POWER CHARGING PORT LANTERN ON ...

Page 7: ...ency use When AC charging is engaged the lantern is not operating Using the 120 Volt AC Power Supply The PS50LRB Rechargeable Portable Power Station Radio Lantern comes with 1 AC On Off Switch Slide switch to turn the AC Power Supply on and off 2 120 Volt AC Power Outlet 3 AC Power Supply ON Status Indicator red LED lights when AC outlet is turned on red LED flashes on and off when faulted 4 AC Po...

Page 8: ...rge the Internal Backup System Battery OPERATING THE LANTERN The Lantern is controlled by the Lantern ON OFF Rocker Switch on the back of the unit see the Control and Function Guide on page 5 Note When the 12 Volt DC Detachable Battery Pack power runs low and no 12 Volt DC power source is available the Lantern will shut down The Radio and LED Backup Light will continue to run as long as the Intern...

Page 9: ...onse directly to the local NWS offices NWS offices have set up pre arranged agreements to facilitate and speed the process NWR and the Emergency Alert System EAS use the same digital protocols and NWR is the primary means for NWS alerts to activate the EAS The Federal Communications Commission FCC amended the EAS rules in 2002 and adopted numerous codes NWS introduced the new codes on June 30 2004...

Page 10: ...Y OR PROPERTY DAMAGE NEVER grasp the glass bulb directly It can shatter DO NOT TWIST to remove the bulb it pulls straight out of the socket Battery Replacement Disposal Battery Replacement When it will no longer holds a charge the Rechargeable Battery Pack can be replaced with a new VEC1198BAT Battery Pack Contact Customer Service toll free at 800 54 HOW TO to order this part The Internal Backup P...

Page 11: ...horized Service Center for repair or replacement at our option Proof of purchase may be required Black Decker owned and authorized Service Centers are listed under Tools Electric in the yellow pages of the phone directory and on our website www blackanddecker com This warranty does not apply to accessories This warranty gives you specific legal rights and you may have other rights which vary from ...

Reviews: