• EXTENSION CORDS.

Make sure your extension cord is in good condition. When using an extension cord, be sure to

use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. The following table shows the correct size to use depending on cord length
and nameplate ampere rating. If in doubt, use the next heavier gage. The smaller the gage number, the heavier the cord.

SAFETY GUIDELINES / DEFINITIONS

DANGER:

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING:

Indicates a potentially hazardous situation which, if not  avoided, could result in death or serious injury.

CAUTION: 

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION:

Used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may

result in property damage.

RISK OF UNSAFE OPERATION.

When using tools or equipment, basic safety precautions should always be followed to

reduce the risk of personal injury. Improper operation, maintenance or modification of tools or equipment could result in
serious injury and property damage. There are certain applications for which tools and equipment are designed. Black &
Decker strongly recommends that this product NOT be modified and/or used for any application other than for which it was
designed. Read and understand all warnings and operating instructions before using any tool or equipment.

SAVE THESE INSTRUCTIONS

THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE POWER STATION RADIO
LANTERN MODEL PS50LRB.

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

This product or its power cord contains lead, a chemical known to the State of California to cause cancer and

birth defect or other reproductive harm. Wash hands after handling.

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK:

Do not expose this unit to rain or moisture; and never

submerge this unit in water or any other liquid.
• When using the 120 Volt AC Adapter, do not use near water, such as a bathtub, sink or laundry, in a wet basement or
next to a swimming pool.
• Never insert anything other than the supplied 12 Volt DC or 120 Volt AC Adapter into the unit’s 12 Volt DC Outlet or
Power/Charging Port. Do not use any accessory not recommended or provided by the manufacturer.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• Do not disassemble the main body of the unit. Other than the removable 3Ah, 12 volt battery pack and the 9 watt compact
fluorescent (CFL) bulb, there are no user-replaceable parts. 
• DO NOT operate any of the unit’s features unless unit is fully assembled.

Minimum Gage for Cord Sets

Volts 

Total Length of Cord in Feet

120V

0-25

26-50

51-100

101-150

(0-7,6m)

(7,6-15,2m)

(15,2-30,4m)

(30,4-45,7m)

240V

0-50

51-100

101-200

201-300

(0-15,2m) (15,2-30,4m)

(30,4-60,9m)

(60,9-91,4m)

Ampere Rating
More

Not more

American Wire Gage

Than

Than

0   -

6

18

16

16

14

6      -

10

18

16

14

12

10  -

12

16

16

14

12

12 -

16

14

12

Not Recommended

2

PS50LRB_Manual_120106  12/1/06  11:25 AM  Page 2

Summary of Contents for PS50LRB

Page 1: ... 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER TO REDUCE THE RISK OF INJURY THE USER MUST READ AND UNDERSTAND THE INSTRUCTION MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Cat PS50LRB Form 90510946 SEP...

Page 2: ...ng and balance at all times DISCONNECT APPLIANCES Disconnect the appliance from the power supply when not in use before servicing and when changing accessories such as blades and the like AVOID UNINTENTIONAL STARTING Don t carry plugged in appliance with finger on switch Be sure switch is off when plugging in GROUND FAULT CIRCUIT INTERRUPTER GFCI protection should be provided on the circuits or ou...

Page 3: ...for which it was designed Read and understand all warnings and operating instructions before using any tool or equipment SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE POWER STATION RADIO LANTERN MODEL PS50LRB IMPORTANT SAFETY INSTRUCTIONS WARNING This product or its power cord contains lead a chemical known to the State of California to cause canc...

Page 4: ...which can be attributed to any of the following a Improper antenna setup To ensure you get the best available reception extend the built in antenna and adjust its direction to provide maximum reception b Improper tuner setup To ensure you are always tuned in to receive the NOAA alerts check the National Weather Service website http www nws noaa gov nwr nwrbro htm for the signal frequency in your a...

Page 5: ...harge backup batteries Battery Charge Level and Charging Indicators Collapsible Handle Hanging Hook Protective cage Protective Features Automatic Overload Built in protection against overload in the event the AC outlet draws more than 50 watts power to the unit s outlet will automatically shut off Ground Fault Circuit Interrupter GFCI The GFCI protects the unit and the user by sensing imbalances i...

Page 6: ...ND CRANK LED INDICATOR 12 VOLT DETACHABLE BATTERY PACK COLLAPSABLE HANDLE HANGING HOOK DYNAMO HAND CRANK WHEN COLLAPSED SEE BELOW DYNAMO HAND CRANK ALERT LED INDICATOR RADIO TUNER KNOB RADIO BAND STATION DISPLAY ALARM LOCK LED INDICATOR RADIO POWER LED INDICATOR ALERT ON OFF PUSHBUTTON RADIO BAND SELECTOR OFF AM FM WX VOLUME CONTROL KNOB ALARM LOCK ON OFF PUSHBUTTON POWER CHARGING PORT LANTERN ON ...

Page 7: ...ency use When AC charging is engaged the lantern is not operating Using the 120 Volt AC Power Supply The PS50LRB Rechargeable Portable Power Station Radio Lantern comes with 1 AC On Off Switch Slide switch to turn the AC Power Supply on and off 2 120 Volt AC Power Outlet 3 AC Power Supply ON Status Indicator red LED lights when AC outlet is turned on red LED flashes on and off when faulted 4 AC Po...

Page 8: ...rge the Internal Backup System Battery OPERATING THE LANTERN The Lantern is controlled by the Lantern ON OFF Rocker Switch on the back of the unit see the Control and Function Guide on page 5 Note When the 12 Volt DC Detachable Battery Pack power runs low and no 12 Volt DC power source is available the Lantern will shut down The Radio and LED Backup Light will continue to run as long as the Intern...

Page 9: ...onse directly to the local NWS offices NWS offices have set up pre arranged agreements to facilitate and speed the process NWR and the Emergency Alert System EAS use the same digital protocols and NWR is the primary means for NWS alerts to activate the EAS The Federal Communications Commission FCC amended the EAS rules in 2002 and adopted numerous codes NWS introduced the new codes on June 30 2004...

Page 10: ...Y OR PROPERTY DAMAGE NEVER grasp the glass bulb directly It can shatter DO NOT TWIST to remove the bulb it pulls straight out of the socket Battery Replacement Disposal Battery Replacement When it will no longer holds a charge the Rechargeable Battery Pack can be replaced with a new VEC1198BAT Battery Pack Contact Customer Service toll free at 800 54 HOW TO to order this part The Internal Backup P...

Page 11: ...horized Service Center for repair or replacement at our option Proof of purchase may be required Black Decker owned and authorized Service Centers are listed under Tools Electric in the yellow pages of the phone directory and on our website www blackanddecker com This warranty does not apply to accessories This warranty gives you specific legal rights and you may have other rights which vary from ...

Reviews: