background image

 

 

Tempest Lantern 

Owner’s Manual 

Natural Gas

 (sku#

 

94900746)  -  

Propane

 (sku# 94900756) 

Tested and 
listed by

 

 

Portland 
OR

 

ANSI Z21.97-2017 / CSA 2.41-2017, CSA 2.17-2017 

Outdoor Decorative Gas Appliances 

Report # 0028GM083S 

 

WARNING:  For Outdoor Use Only.   Installation and service must be performed by a 
qualified installer, service agency or the gas supplier.  

 

 

WARNING:  If the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury, or loss of life. 

 

 

WARNING:  Do not store or use gasoline, or other flammable vapors and liquids, in the 
vicinity of this or any other appliance. 
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other 
appliance. 

 

DANGER:  FIRE OR EXPLOSION HAZARD

 

If you smell gas: 

 

Shut off gas to the appliance. 

 

Extinguish any open flame. 

 

If odor continues, leave the area immediately. 

 

After leaving the area, call your gas supplier or fire department. 

Failure to follow these instructions could result in fire or explosion, which could cause 
property damage, personal injury, or death. 

 

 

 

CARBON MONOXIDE 

HAZARD 

 

This appliance can produce 
carbon monoxide which has 
no odor. 

 

Using it in an enclosed 
space can kill you. 

 

Never use this appliance in 
an enclosed space such as a 
camper, tent, car or home. 

 

Hot glass will 

cause burns. 

 

Do not touch 
glass until 
cooled. 

 

Never allow 
childern to 
touch glass.

 

 

 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

$10.00 

 Copyright 2020, T.I.     

 

Part # 100-01535

 

 

Summary of Contents for 94900746

Page 1: ...e shall not be stored in the vicinity of this or any other appliance DANGER FIRE OR EXPLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal in...

Page 2: ...ive Appliances The listing label is chained to the appliance A copy is shown to the right Important Registration and Service Information No other Tempest Lantern has the same serial number as yours The serial number is on the safety label attached by a chain near the control panel This serial number will be needed in case you require service of any type To receive full warranty coverage you will n...

Page 3: ... Required 6 Recommended Order of Installation 6 Placement Requirements 7 Clearances 7 Gas Line Requirements 8 LP and NG Configuration 8 Gas Line Connection 8 Piezo Ignitor Knob 8 Post Mount and Control Cover Installation 9 Lantern Assembly 10 Post or Pier Mounted Lantern Optional 11 Wall Mounted Lantern Optional 12 Before You Begin 13 Operating Instructions 13 Maintaining Your Lantern 15 Winterizi...

Page 4: ...e LP Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard Direct questions about the type of fuel used to your dealer A label is placed on the control panel to show which fuel the Lantern is designed for in addition NG units have 25 burner holes LP units have 49 burner holes Contact your local building officials to obtain a permit and informat...

Page 5: ...allation Options For Outdoor Installation Only For Fixed Line Installations Only Wall Mount Post Mount Pier Mount Gas Specifications NG LP Input Rating Btuh 20 000 20 000 Orifice Size DMS 50 55 Burner Ports 25 Holes 49 Holes Manifold Pressure 7 wc 11 wc Max Inlet Pressure 7 wc 11 wc Dimensions NOTE Side clearances are measured from the glass Top clearances are measured from the glass frame Lantern...

Page 6: ...h the Lantern head location identified prepare and mount the Lantern head support pillar post or wall mount This order of installation may need to be modified due to individual installation conditions NOTE sections 4 5 6 and 7 of this page detail gas connections to the Lantern head 3 GAS SUPPLY The Lantern requires 20 000 BTU input natural gas or LP A shut off valve and 12 inches of flex line are ...

Page 7: ...antern in these locations are recommended In places where the controls beneath the Lantern may be submerged under water Submerging of any part of its controls will require complete replacement of the controls Clearances The distance from ground level to the top of the Lantern shall be a minimum of 7 ft 2 1M where installed within 2 feet 0 6M of public walkways e g sidewalk shared walkway between t...

Page 8: ...nd gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1 2 psig For pressures less than 1 2 psig isolate the gas supply piping by closing the manual shut off valve Leak test all gas line joints and the gas control valve prior to and after starting the Lantern LP and NG Configuration This Lantern is shipped eith...

Page 9: ...ch the cover b Slide the control cover over the post HINT Use low tack tape to protect the post from scratches NOTE When installing the post make sure the post is positioned with the mounting holes 45 offset from the front The post mount has obround holes that allow 20 of rotation 10 in each direction c Attach the gas line WARNING Take care when handling the Lantern assembly to not damage the gas ...

Page 10: ...h the hole on the burner top b Slide the glass panels into place by aligning each panel with one of the slots in the top plate of the Lantern Support the glass panels as you lower them into place to avoid damaging them HINT Make sure the glass is clean before installing and handle with soft gloves or other non marking material e g paper towel c Place the rain cap on the top of the Lantern glass as...

Page 11: ...atform with the optional post base kit If the post is placed in a remote location it may be sunk into the ground using concrete or other suitable means See the post or post base kit for assembly and installation instructions Post Mount included with torch Post Base separate kit Deck Mount post or pillar Gas Line Deck Surface or equivalent Post Mount included with torch Free Standing Post Mount Gas...

Page 12: ...tern Piezo Wall Mounted Lantern Optional The tempest Lantern may be mounted to an external wall an optional wall mount kit Make sure that all clearances are can be maintained in your application See the wall mount kit for assembly and installation instructions ...

Page 13: ...he valve control in if the Lantern does not light By pushing the valve control in you are allowing gas to flow to the Lantern creating an explosion hazard If the Lantern does not light push the valve control in and rotate the valve to the OFF position Lighting the Lantern DRY WEATHER NOTE If re lighting make sure the Lantern remains off for a minimum of 5 minutes before re lighting 1 Push valve co...

Page 14: ...e control in Lantern must light within 5 seconds Remove the wand lighter After Lantern lights continue to hold valve control in for 15 seconds Note if Lantern does not light with a wand lighter directly next to the burner with the valve control pressed in in the START HIGH position gas is not reaching the Lantern Turning the Lantern Off 1 Push valve control in and turn clockwise to the OFF positio...

Page 15: ... you break one or need to replace a piece use only 3 16 thick tempered glass supplied by your Tempest Lantern dealer To inspect for or clean debris out of the inside of your Lantern remove one piece of glass This will provide access to the inside of your Lantern Once your glass piece is out remove the pyramid shaped piece with the rings on the top by lifting it straight up once you are clear of th...

Page 16: ...Base Cover 1 250 05514 5 Flame Spreader Assy NG 1 250 01790 5 Flame Spreader Assy LP 1 250 01791 6 Glass 4 250 01251 7 Piezo Knob Black 1 250 01255 ID Description Qty Part 8 Piezo Igniter w Screws 1 250 01254 9 Magnet w Nut 1 250 01268 10 Gas Valve w Nut 1 250 01253 11 Flex Pipe 3 8 od x 8 BLK 1 250 00666 12 Orifice Burner 55 1 250 00409 12 Orifice Burner 50 1 250 00753 13 Pilot Electrode S I T Pi...

Page 17: ...vailable capacity e g pool heaters furnaces hot water tanks etc Flames are not Spiral Lantern was just turned on Windy Condition It takes 5 to 10 minutes for the Lantern to start up and the flame to form a spiral Wind will influence the flame shape Glass is Sooting Wrong fuel type for Lantern Burner or burner orifice may be dirty or blocked Windy Condition Make sure LP head with LP gas and NG head...

Page 18: ... caused by normal wear and tear such as discoloration Also excluded is damage to the unit caused by abuse improper installation modification of the unit drilling of the orifices or the use of fuel other than that for which the unit is configured Units are shipped for either natural gas or propane Confirm fuel configuration with your installer 9 Damage to stainless steel surfaces caused by fingerpr...

Page 19: ...Index 19 Travis Industries Inc 5 21 20 1535 Tempest Lantern Piezo ...

Page 20: ...antern DRY WEATHER 13 Lighting the Lantern WET WEATHER 14 Listing Details 2 LP and NG Configuration 8 Maintaining Your Lantern 15 Operating Instructions 13 Order of Installation 6 Overview 2 Packing List 6 Piezo Ignitor Knob 8 Placement Requirements 7 Post Mount and Control Cover Installation 9 Post or Pier Mounted Lantern 11 Registration 2 Replacement Parts 16 Troubleshooting Table 17 Turning the...

Reviews: