ENGLISH
(Original instructions)
8
appliance.
♦
Do not cover or obstruct the sides of the appliance,
and leave a minimum space of 50cm front other walls,
ceiling..
♦
The plug must be easily accessible so it can be discon-
nected in an emergency.
♦ To achieve the highest efficiency from the appliance
it should be situated in a place where the atmospheric
temperature is between 12 and 32ºC.
♦
Ensure that the extraction pipe remains in a horizontal
position. (Fig 2)
♦
Do not add new sections to the extraction tube provided,
as it could cause the appliance to malfunction.
♦ The appliance should be used with its base feet fitted.
♦
The appliance should be used with its wheels attached.
Assembly of the exhaust hose
♦
Lengthen one head of the hose, and spin the exhaust
hose into exhaust connector (counterclockwise).
♦
Caution: Exhaust pipe is 40 cm~160 cm long (including
adapter).
♦
The length of exhaust pipe is especially designed in
accordance with the specification of the air conditioner.
Please do not use other exhaust pipes of different leng-
ths or materials, in such way failure may be caused.
INSTALLATION OF WINDOW KIT
(Fig 3)
♦ Partially open the window and then fix the window kit to
the window.
♦
The window kit can be installed on most of normal and
vertical windows and it is adjustable.
♦
Fix the other end of the heatexhausted hose to the
airoutlet window kit.
Instructions for use
Use:
♦
Unroll the cable completely before plugging it in.
♦
Connect the appliance to the mains.
♦
Press the ON/OFF button, the unit will enter in cooling
mode with low fan speed.
♦
Press the mode button to select cooling dehumidifying,
fan mode.
Fan Speed
♦
Under the cooling and the fan mode, the speed goes as
follow:
♦ Lower Fan→Mid Fan> High Fan.
♦ In dehumidifier mode, the fan operates at low speed.
Timer mode
♦
I The operating time of the device can be controlled from
1 ~ 24h.
♦
Push the button
♦
You can program the time with the up and down buttons
♦
The timer self-off function is only available when the
device is on.
♦
The button (up) up and (down) down is used to set the
temperature and the timer.
♦
In cold mode and heat mode, the temperature program-
ming arc ranges from 16º ~ 31ºC.
Swing
♦
Press this button to control the movement of the louver.
Cooling mode:
♦
Press mode to select cooling mode, cooling mode
indicator turns on.
♦
Press Up or Down to adjust temperature in a range of
8ºC~30ºC.
♦
When the up or down is pressed once, temperature will
go up or down by 1ºC every time.
♦
Pressing Up and Down at the same time, we will alterna-
te between degrees Fahrenheit and degrees Celsius
♦
Press speed to select high, mid or low fan speed.
Fan mode:
♦
Press mode to select fan mode fan indicator turns on.
♦
Press speed to select high, mid or low speeds.
♦
Temperature is not adjustable.
♦
Press Swing to turn off or turn on the up/down swing
function.
Dehumidifying mode:
♦
Press “MODE” to select dehumidifying mode, dehumidif-
ying mode indicator turns on.
♦
Remove the plug of drainage cap, insert a tube and put
the other side of the tube into water containers or drain
channels.
♦ When entering dehumidification mode, if the room tem
-
peratures is ≥17ºC, the compressor will start to work.
♦ If the room temperature is ≤15ºC, compressor stops;
when the temperature rises back to ≥17ºC, the com
-
pressor restarts (the compressor shall meet the 3minute
delay protection function).
♦ In dehumidification mode, the fan run in low speed by
default, and the wind speed are not adjustable. ·Tempe-
rature cannot be set.
♦ NOTE: When the dehumidification function is in use, the