background image

8

X

Turn over the engine using the manufacturer's guidelines, 
typically in 3 to 5 second bursts.

The high current engine starting function requires a resting/
cooling period between tries. The battery charger will switch 
back to regular charge mode after 5 seconds and will not 
allow operation in the Engine Start mode for 4 minutes. 

X

Wait 4 to 5 minutes before a second attempt at starting the 
engine, if needed.

During the rest period, the battery is charging at 2 A. 

X

After the engine starts, follow the steps outlined in “Safety 
instructions” at the front of this manual to disconnect the 
battery charger.

Alternator check (fig. A)
Warning! 

Check only 12 Vdc systems.

Part 1 (no load)

X

Make sure that there is no load on the alternator by turning 
off all the vehicle's accessories. 

The battery must be fully charged before testing the 
alternator. 

X

Run the engine long enough to achieve normal idle speed 
and verify that there is a no-load voltage.

X

Press the alternator check pushbutton (13) to start the 
check.

X

The alternator good LED (8) will light to indicate that the 
alternator is good, or 

F07

 will be displayed on the digital 

display (1) to indicate that the alternator is out of typical 
voltage range.

X

Press the alternator check pushbutton (13) again to stop the 
test.

Part 2 (under load)

X

Load the alternator by turning on as many accessories as 
possible, except for air-conditioning and defrost.

X

Press the alternator check pushbutton (13) to start the test.

X

The alternator good LED (8) will light to indicate that the 
alternator is good, or 

F07

 will be displayed on the digital 

display (1) to indicate the alternator is out of typical voltage 
range.

X

Press the alternator check pushbutton (13) again to stop the 
test.

If the first alternator check indicates a good alternator and 
the second indicates the alternator is not good, the problem 
could be caused by any of the following:

X

Loose fan belts.

X

An intermittent diode failure.

X

Bad connections between the battery and alternator and/or 
ground.

Note:  

The battery voltage pushbutton (14) is disabled in the 

alternator check mode. 

Note:  F07

 may display because a number of extra accessory 

loads have been added to the charging system, thereby 
increasing current demand from the alternator. Make sure 
that the alternator is rated to support the application.

Note:  

This check may not be accurate for every make, 

manufacturer and model of vehicle.

Approximate charging times

The battery charger will automatically adjust the charge rate 
as the battery becomes charged and stop charging when the 
battery is fully charged. Deep cycle batteries may require 
longer charging times.

For estimates of the time it takes to charge a battery, refer 
to the following table:

*NR = Not recommended at 2 A - use a higher charge rate.

The times shown in the table above are approximate and 
refer to a 50 Ah automotive battery. 

Example

A 50 Ah, 12 Vdc battery is discharged (50%). To determine 
the time it takes to charge at the 10 A rate, see the chart 
above under "50%" and "at 10 A rate."

The battery charging times will vary depending on the size, 
age and condition of the battery. Smaller batteries should be 
charged at a lower rate (2 A) and an extra hour added to the 
charge time.

Maintenance

Your Black & Decker tool has been designed to operate over 
a long period of time with a minimum of maintenance. 
Continuous satisfactory operation depends upon proper tool 
care and regular cleaning.

Warning! 

Before performing any maintenance or cleaning on 

the appliance, unplug the appliance.

X

From time to time wipe the appliance with a damp cloth. Do 
not use any abrasive or solvent-based cleaner. Do not 
immerse the appliance in water.

X

After each use, clean the battery clamps (5) and be sure to 
remove any battery fluid that will cause corrosion of the 
battery clamps (5).

X

Clean the outside case of the battery charger with a soft 
cloth and, if necessary, mild soap solution.

X

Do not allow liquid to enter the battery charger. Do not 
operate when the battery charger is wet.

% of charge in the battery

Rate

75%

50%

25%

0%

2A

7 hrs

14 hrs

NR*

NR*

10A

1.4 hrs

2.8 hrs

4.2 hrs

5.5 hrs

30A

1 hrs

1.2 hrs

1.7 hrs

2.2 hrs

Summary of Contents for BDV1085

Page 1: ...UK Ireland Australia New Zealand ...

Page 2: ...2 ...

Page 3: ...ecified in this manual Power cord safety Warning Neveraltertheacpowercordorplug Ifitwillnotfit haveaproperoutletinstalledbyaqualifiedelectrician Improper connection may result in an electric shock Specific safety instructions for battery chargers This product must be earthed Always check that the power supply corresponds to the voltage on the rating plate Power plugs must match the outlet Never mo...

Page 4: ...ychargerasfarawayfromthebatteryas theleadswillallow Thebatterychargercontainsswitches that may create a spark X Donot placethe batterycharger above or stand thebattery charger on top of the battery X Explosive gases may collect near the ground Locate the battery charger as high as possible above ground level X Do not use power tools in the charging area X Do not smoke or have naked flames in the c...

Page 5: ...ating covers to the battery posts Charging a battery disconnected from the circuit Warning Incorrectconnection batteryshortcircuit locationof battery and location of the battery charger may create a hazard Make sure that adequate preparation has been made before proceeding If the battery is not already removed from the circuit follow the manufacturers instructions to remove the battery before char...

Page 6: ...red Battery voltage pushbutton 14 This pushbutton enables a check to measure the battery voltage Equalize pushbutton 9 This is a recessed pushbutton used to start the equalize process Control panel LEDs fig A WET LED 10 lights when the battery type selector is on wet battery type Maintenance free LED 11 lights when the battery type selector is on maintenance free battery type Float charge LED 6 li...

Page 7: ...y when equalizing The frequency which the equalization process needs to be run depends on the use of the battery The more the battery is used the more undercharged it becomes thus the more frequently the battery should be equalized Do not use this mode on sealed or valve regulated batteries This mode is only meant for wet unsealed vented batteries X Make sure that there are no flammable sources ne...

Page 8: ...rnatorand or ground Note The battery voltage pushbutton 14 is disabled in the alternator check mode Note F07 may display because a number of extra accessory loads have been added to the charging system thereby increasing current demand from the alternator Make sure that the alternator is rated to support the application Note This check may not be accurate for every make manufacturer and model of v...

Page 9: ... 30 minutes and reconnect X Make sure that there is ample ventilation before resuming operation F06 Reverse polarity F06 is displayed if the connections to the battery s positive and negative terminals are incorrect Follow the steps outlined in Safety instructions at the front of this manual to disconnect the ac power cord and the battery clamps 5 and then reconnect to the battery with the correct...

Page 10: ... This guarantee statement is in addition to and in no way prejudices your statutory rights The guarantee is valid within the territories of the Member States of the European Union and the European Free Trade Area If a Black Decker product becomes defective due to faulty materials workmanship or lack of conformity within 24 months from the date of purchase Black Decker guarantees to replace defecti...

Page 11: ...11 ...

Page 12: ...N HFNHU XVWUDOLD 3W WG 7HO OHWFKHU 5RDG 0RRURROEDUN D 9LFWRULD 1HZ HDODQG ODFN HFNHU 7HO XJR RKQVWRQ ULYH D 3HQURVH XFNODQG 1HZ HDODQG 8QLWHG LQJGRP ODFN HFNHU 7HO DWK 5RDG D 6ORXJK HUNVKLUH 6 HOSOLQH 90507193 12 06 ...

Reviews: