ACV Bandwidth
45 Hz to 400 Hz
Crest Factor
≤ 3 at fulls scale up to 500 V, decreasing linearly to ≤
1,5 at 1000 V
Display
6,000 counts backlit liquid crystal with bargraph
Overrange indication
"OL" is displayed
Auto Power Off
15 minutes (approximately) with disable feature
Polarity
Automatic (no indication for positive) ; Minus (-) sign
for negative.
Measurement Rate
2 fois par seconde, nominal
Low Battery
Indication
is displayed if battery voltage drops below operating
voltage
Battery
One 9 volt (NEDA 1604) battery
Fuses
mA, µA ranges; 0,8 A/1000 V ceramic fast blow
A range; 10 A/1000 V ceramic fast blow
Operating
Temperature
5 °C to 40 °C ( 41 °F to 104 °F)
Storage Temperature
-20 °C to 60 °C to 140 °F
Operating Humidity
Max 80 % up to 31 °C (87 °F) decreasing linearly to
50 % at 40 °C (104 °F)
Storage Humidity
< 80%
Operation Altitude
7000ft. (2000 meters) maximum.
Weight
436 g (includes holster).
Size
182 x 82 x 59 mm (boîtier compris)
Safety
This meter is intended for origin of installation use and
protected, against the users, by double insulation per
EN61010-1 and IEC61010-1 2 Edition (2001) to Category
IV 600V and Category III 1000V; Pollution Degree 2. The
meter also meets UL 61010-1, 2
nd
Edition (2004), ndCAN/
CSA C22.2 No. 61010-1 2
nd
Edition (2004), stand UL
61010B-2-031, 1
st
Edition (2003)